Date - Time - Siemens BTC-BR User Manual

Tachograph programmer and calibrator
Hide thumbs

Advertisement

Table of Contents
BTC-BR User's Manual
2.4.9.2 – Date - Time
Steps
Contents of the display
1
1. INSTALLATION
2. DATE - TIME ←
3. MANUFACT DATA
5
6
(
/
) – Scroll
2
1. MTCO TIME ←
2. MTCO TIME ZONE
3. MTCO OVER TIME
6
(
) – Scroll
SYSTEM TIME UTC
3
DATE:
TIME:
F1 – Adjust
Note: in this function should be adjust the value of hours always with 01 (one) hour more than the
desired. This is necessary because the Tachograph Programmer / Calibrator leaves the factory
with a pre-adjusted time zone in less one hour (–01:00hs) than the desired time to adjust. This
difference is compensated at the time of adjustment of hours. For instance: in case of wanting
to adjust the hours to 12:10 pm, you must enter 13:10hs and the calibrator itself will correct the
difference.
ATTENTION: Every time when there is change of hours in MTCO, you must open the
1. MTCO TIME
4
2. MTCO TIME ZONE ←
3. MTCO OVER TIME
5
6
(
) – Scroll
/
TIME ZONE
5
-01:00 h
F1 – Adjust
1. MTCO TIME
6
2. MTCO TIME ZONE
3. MTCO OVER TIME ←
5
(
) – Scroll
Keys
E
(E) Enter
E
(E) Enter
05 / 01 / 2001
10:38:25
E
(C) Exit
disk compartment and correct the time of recording in the disk diagram.
See "Manual of Operation of MTCO".
E
(E) Enter
(C) Exit
E
C
(E) Enter
Procedures
Select Date - Time
This function will access a sub-menu in which
will be possible to adjust date/time, time zone
and over time.
Select MTCO Time
This function will allow correcting the current
date (day, month and year) and hour/minutes.
This function is necessary only if the MTCO
present an error greater than 01 day (or 24
hs).
To change the values of interest, press E for
change of field to each value entered and, at
the end, press F1 and the modification will be
effective.
Select Time Zone
This function adjusts the value of the time
zone to be compared with the world
standard time (UTC). It is pre-adjusted in
less one hour (-01:00).
If you do not want to run the process of the
previous observation, simply reset the time
zone. For this, enter the value zero twice,
press E, and then F1. We recommend not
changing the original settings of Tachograph
Programmer / Calibrator.
This function is not enabling to tachograph
currently in use. Program dates and times in
which the MTCO changes automatically to over
time and must not be changed under any
circumstances.
Select next function.
19