3. Slide the foam air diverter and front air cover
forward to remove from the dryer.
Front Air Cover
Foam Air Diverter
4. Disconnect the drum lamp, outlet thermistor,
and touch sensor wire harness and remove it
from the 5 wire retainers.
Disconnect
Disconnect
5. Position the wire harness out of the way.
6. Remove the 3 Phillips-head screws under the
7. Remove the 4 Phillips-head screws that attach
Disconnect
8. Remove the 3 Phillips-head screws that secure
9. Lift the drum support up, pull the bottom out,
– 33 –
condenser that secure the drum support to the
cabinet.
the drum support to the cabinet.
the condensation tank housing to the cabinet,
and then pull and twist the housing forward
slightly until the housing tab is free from the
frame.
and then disengage the drum support tab from
the control panel support bracket.
Condensation Tank Housing
Tab
Tab
Control Panel Support Bracket