SECTION 4—SAFETY INSPECTION/TROUBLESHOOTING
All Wheelchairs

General Troubleshooting

SYMPTOM
Limited driving distance.
Batteries not charging.
Batteries draw excessive
current when charging.
Charger indicator shows low
charge level immediately
after charging.
Battery indicator flashes the
charge level is low
immediately after recharging.
Wheelchair will not drive.
Motor "chatters" or runs
irregularly.
Only one drive wheel turns.
Joystick erratic or does not
respond as desired.
Wheelchair does not
respond to commands.
Power indicator off - even
after recharging.
®
Pronto
M51
Base with SureStep
PROBABLE CAUSE
Batteries not charged long
enough.
Batteries weak; wont hold
charge.
Charger not working.
Battery connections loose.
No current at wall outlet.
Bad connection on charger,
charger cable, plug or
internal wiring problem.
Battery failure.
Batteries weak, wont hold
charge.
Electrical malfunction.
Charger malfunction.
Weak Batteries.
Charger malfunction.
Electrical malfunction
Motor release levers are
disengaged.
Batteries require charging.
Charger plugged in.
Circuit breaker tripped.
Electrical malfunction.
Electrical malfunction.
One motor lock is
disengaged.
Electrical malfunction.
Controller programmed
improperly.
Poor battery terminal
connection.
Electrical malfunction.
®
24
SOLUTIONS
Charge batteries overnight or ensure 8 hours of
charge time between use. Ensure correct setting
on charger.
Replace Batteries.
Have charger replaced. Contact Dealer/Invacare.
Check all connections. Secure connections.
Switch to another wall outlet.
Replace charger or internal repairs may be
required. Contact Dealer/Invacare.
Have batteries checked for shorted cell. Replace
if necessary.
Replace Batteries.
Contact Dealer/Invacare.
Replace charger. Contact Dealer/Invacare.
Replace batteries.
Replace charger. Contact Dealer/Invacare.
Contact Dealer/Invacare.
Engage motor release levers.
Charge batteries. Make sure the setting on the
charger is correct.
Unplug charger from wall outlet before
operating the wheelchair.
Reset circuit breaker. If breaker trips again, it
may indicate need for internal repair. Contact
Dealer/Invacare.
Contact Dealer/Invacare.
Contact Dealer/Invacare for service.
Engage motor lock.
Contact Dealer/Invacare for service.
Reprogram controller (Refer to electronics
manual supplied with wheelchair).
Have terminals cleaned.
Contact Dealer/Invacare for service.
Part No. 1148076