Indicators

This projector has two indicators, each of which shows the operation condition of the projector.
The following offer solutions to possible problems. If these problem persist, turn the projector off and consult your dealer.
STATUS indicator
Normal condition
POWER
STATUS
Steady red
Off
Off
Blinking red
Steady green
Steady green
Steady green
Blinking green
Abnormal condition
POWER
STATUS
Blinking green about
Off
30 seconds after
power on.
Steady amber
Steady green
about 5 seconds after
power on.
Steady green about
Blinking green
20 seconds after
power on.
Steady red about 10
Steady green
seconds after power
on.
Steady green
Blinking red
Steady red about 5
Off
seconds after power
on.
N/A
N/A
EN-26
CONDITION
Stand-by
Power up process (About 4 seconds)
The power is on. (Normal condition)
Lamp cooling down. (About 90 seconds)
Lamp lit up (About 60 seconds)
CONDITION
Lamp failure
Color wheel failure
Fan failure
Abnormal temperature
95% Lamp life exceed
Lamp life end
Lamp cover open
POWER indicator
NOTE
POSSIBLE SOLUTION
Replace the lamp and reset the lamp hour.
Contact your dealer.
Check if the fan is clogged with dust or dirt and
clean it.
If the above solution is not effective, contact your
dealer.
Clean the ventilation grilles.
Relocate the projector to a cooler place.
For the directly shut down, it will check the
temperature first, if it's too high, it will start
cooling for 90 seconds.
If it's abnormal shut down in the previous time,
while the temperature is too high, it will start the
cooling process after 90 seconds when the
temperature is still too high.
Replace the lamp and reset the lamp hour.
Replace the lamp and reset the lamp hour.
Put back the lamp cover.