Canadian Wiring - auxiliary terminal block and connections
Fitting the auxiliary terminal block (see diagram below).
Fig. 7
For Canada only (Not for U.S.A.)
▶ Connect the red wires from the left hand terminal of the
new block to the L1 terminals in the unit.
▶ Connect the blue wires from the right hand terminal of the
new block to the L2 terminals in the unit.
▶ Push and click the auxiliary terminal block onto the
louvered rail in the backplate.
Connecting the supply cable - Canada only - not for the USA.
The WH36 requires a 180A 240V AC
single phase supply protected by a double
pole circuit breaker rated for at least 162A.
The power cable size and the installation must be in
accordance with the Canadian Electrical Code, C22.1-02.
The incoming hole diameter on auxiliary terminal block can
accept up to 1/0 AWG size cables.
The cable entry is via the 1 ¼ inch cable entry hole on the
bottom right hand edge of the back plate.
Strip back the insulation on the power wires about ½ inch.
Connect the ungrounded conductors to the terminals "L1"
and "L2" on the auxiliary terminal block.
6 720 647 022 (2013/04)
Any insulation on the ground wire should be stripped back
about ¾ inch. The ground lead must be connected to the
pillar terminal marked "GR."
Make sure the terminal block screws are tightened
securely. Loose connections can cause wires to heat up.
Make sure that the ground wire is wrapped around its
terminal stud and into the saddle washer. The nut should be
tightened securely.
Attach the front cover and tighten the retaining screws.