Download Print this page

King Canada KAC-410 Instruction Manual page 2

Portable air cleaner with remote control

Advertisement

SPECIFIC SAFETY INSTRUCTIONS
FOR AIR CLEANERS
1. FOR YOUR OWN SAFETY, READ
INSTRUCTION
MANUAL
BEFORE
OPERATING. Learn the tool's application
and limitations as well as the specific
hazards peculiar to it.
2. DO NOT ATTEMPT TO REMOVE OR
REPLACE THE FILTER(S) WHILE THE
MACHINE IS IN OPERATION. MAKE
SURE AIR CLEANER IS DISCONNECTED
FROM THE POWER SOURCE.
3. DO NOT OPERATE THE AIR CLEANER
WITHOUT THE FILTERS IN PLACE TO
AVOID EXPOSURE TO ROTATING
PARTS AND OVERLOADING THE
MOTOR.
4. THE USE of filters and attachments
which are not recommended may result
in product damage or the risk of
personal injury.
5. When suspending the Air Cleaner from
MAKE
CERTAIN
the
ceiling
hardware is securely anchored into a
wood structure. Always keep a minimum
of 7 feet between bottom of Air Cleaner
and the floor surface to allow for
adequate head clearance. Also, use only
properly sized chain to prevent the tool
from falling.
6.
TO
REDUCE
THE
RISK
ELECTRICAL SHOCK, do not expose to
water or rain, and do not lift the Air
Cleaner by the power cord. DO NOT use
the power cord as a hanging device.
7. When used in the portable application,
MAKE CERTAIN the Air Cleaner is
adequately
supported,
or
securely
clamped to the work surface to eliminate
any potential for movement or damage
from falling.
8. ALWAYS WEAR ADEQUATE EYE
PROTECTION.
9. WHEN NOT IN USE, BE CERTAIN TO
STORE AIR CLEANER IN A SAFE
LOCATION
TO
ELIMINATE
POTENTIAL OF DAMAGE TO THE
POWER
CORD
OR
TRIPPING
HAZARDS.
10. MAKE WORKSHOP CHILDPROOF by
unplugging tools from power source,
using padlocks, or by using a master
switch.
MAINTAIN
TOOLS
11.
CONDITION. Keep filters clean for
optimum
performance.
instructions for changing and cleaning
filters.
12. DANGER: DO NOT use this machine to
filter any metal dust. Combining wood
and metal dust can create an explosive
hazard. This Air Cleaner is intended to be
used to filter non-explosive atmospheres
only.
13. IF YOU ARE NOT thoroughly familiar
with the operation of the Air Cleaner,
obtain advice from your supervisor,
instructor or other qualified person.
14. WARNING: DO NOT operate your Air
the
Cleaner until it is completely assembled
and installed according to the instruction
manual.
15. PLACE POWER CORD IN A SAFE
LOCATION TO ELIMINATE TRIPPING
HAZARDS.
16. USE FACE OR DUST MASK AND EYE
PROTECTION. WARNING: The dust
OF
generated by certain woods and wood
products can be hazardous to your
health. Always operate machinery in
well-ventilated areas and provide for
proper dust removal.
17. WARNING: TO AVOID A POTENTIALLY
DANGEROUS SITUATION, DO NOT
USE AIR CLEANER TO DISSIPATE
FUMES OR SMOKE. This Air Cleaner is
intended for use in non-explosive,
non-metallic atmospheres where only dry
airborn dust is present.
18. SAVE THESE INSTRUCTIONS. Refer
to them frequentely and use them to
instruct other users.
THE
Specifications
Outer filter ................................................................................................5 Microns
Inner filter ..................................................................................................1 Micron
Overall dimensions (LxWxH) ............................................................21" x 17" x 11"
Sound rating @ 3ft. ....................................................................High speed- 69db
IN
TOP
..............................................................................................Medium speed- 67 db
....................................................................................................Low speed- 62 db
Follow
Air flow. ................................................................................High speed- 410 CFM
........................................................................................Medium speed- 362 CFM
..............................................................................................Low speed- 260 CFM
Motor......................................................................................120V, 60Hz, 1 Phase
Weight ..........................................................................................................30 lbs.
GROUNDING
This air cleaner must be grounded. If it
should
malfunction
grounding provides a path of least
resistance for electric current, to reduce the
risk of electric shock. This air cleaner is
equipped with a cord having an equipment-
grounding conductor and grounding plug.
The plug must be plugged into an
appropriate outlet that is properly installed
and grounded in accordance with all local
codes and ordinances.
WARNING:
TO
GROUNDING, DO NOT REMOVE OR
ALTER THE GROUNDING PRONG IN ANY
MANNER.
As received from the factory, your air
cleaner is ready to run on 120V currant.
This air cleaner is intended for use on a
circuit that has an outlet and a plug which
looks like the one illustrated in Fig.1.
A separate electrical circuit should be used
for your tools. This circuit should be no less
than than #12 wire and should be protected
with a 20 amp fuse. Make sure the electric
current is of the same characteristics as
stamped on the machine nameplate.
Running on low voltage will damage the
motor.
THERMAL PROTECTOR
This air cleaner is thermally protected. In
the case of an overload the fuse will blow
SPECIFICATIONS &
ELECTRICAL INFORMATION
and will need to be replaced with an
equivalent 2 amp. fuse.
or
breakdown,
Current
carrying
prongs
Grounding
prong
MAINTAIN
PROPER
EXTENSION CORDS
The use of any extension cord will cause
some loss of power. Use the following table
to determine the minimum wire size
(A.W.G-American Wire Gauge) extension
cord needed. Use only extension cords
which accept the tool's plug.
For circuits that are further away from the
electrical circuit box, the wire size must be
increased proportionately in order to
deliver ample voltage to the motor. Refer to
Fig.2 for wire length and size.
EXTENSION
LENGTH
0-25 Feet
26-50 Feet
51-100 Feet
Grounded outlet
Figure 1
REQUIRED GAUGE
(AWG) 120V LINES
NO.16
NO.16
NO.14
Figure 2

Advertisement

loading