Options Available To Service Engineers; Selecting The Extra Cold Rinse Option; Disabling Pulse Washing; Exiting Diagnostics Mode - Electrolux Diva Service Manual

Hide thumbs Also See for Diva:
Table of Contents

Advertisement

10.5 Options available to Service Engineers

In particular circumstances, i.e. if the user reports unsatisfactory washing results, a special procedure,
available only to Service Engineers, can be used to select two supplementary options designed to improve
performance:
Extra cold rinse.
Disabling of pulse washing (PW), replaced by continuous washing (Ctrl).

10.5.1 Selecting the extra cold rinse option

Using the procedure described below, it is possible to add a supplementary cold rinse in all the
washing programmes. This improves the quality of the rinse in case of
1. Access diagnostics mode (see 10.1)
2. Press buttons S1-S2 simultaneously:
The end of cycle LED indicates the status of the function:
If the end of cycle LED is switched off, the extra rinse is not
selected.
If the end of cycle LED is lit, the extra rinse has been
selected.
3. Press button S1 to activate and deactivate this function.
4. To store the operation in memory: press button S0 and
switch the appliance or wait 60 seconds.

10.5.2 Disabling pulse washing

Certain programmes use the pulse washing system (PW). Using the procedure described below, the
Service Engineer can modify this system so that Ctrl (continuous) washing is used in all those programme
which normally use the PW system. This intensifies the washing action even in delicate programmes.
1. Access diagnostics mode (see 10.1)
2. Press buttons S2-S3 simultaneously till LD2 starts flashing:
The End of cycle LED indicates the status of the function:
If the end of cycle LED is switched off, the continuous
washing system is used.
If the end of cycle LED is lit, the pulse washing system is
used.
3. Press button S2 to activate and deactivate this function.
4. To store the operation in memory: press button S0 and
switch off the appliance or wait 60 second (LD1 ÷ LD6
light)

10.6 Exiting diagnostics mode

1. To exit the diagnostics cycle press button S0 and switch
off the appliance or wait 60 seconds: the LEDs LD1÷LD6
light and the appliance sets in selection mode.
SOI/TD PR
necessity.
29/35
599 35 90-23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Diva_edw1100

Table of Contents