Section 8: Troubleshooting; Table 6: Troubleshooting Digital Clock - Inova OnTimeTM Owner's Manual

Inova ontime digital clock owner's manual
Table of Contents

Advertisement

Inova OnTime Digital Clock Owner's Manual

Section 8: Troubleshooting

The following table contains several trouble conditions you may encounter with the OnTime
Digital Clock and the recommended actions to take to correct the problem.
Note: The up-to-date troubleshooting help is available in the FAQ at
the support tab.
Condition
Clock Face Dark
Clock Shows Incorrect Time
DHCP Message on Clock Face
Service Light Blinking
Service Light On
Determine the IP Address of a
Clock
Clock showing ------
Other Problems
All claims based on information publicly available at time of printing. All other product or service names mentioned in this document may be
trademarks of the companies with which they are associated. © 2007 Inova Solutions. | All rights reserved. 6.12.2007 | page 19
1.
Verify that an Ethernet PoE power injector is present (if required)
and is operating.
2.
Reboot the clock by disconnecting the data cable, counting to five,
and reconnecting the cable.
1.
If the Service Light is illuminated (see below).
2.
If the minutes past the hour are correct, verify the Time Zone and
Daylight Saving Time settings.
1.
The clock has failed to receive an IP address from the DHCP server.
2.
Contact your IT group responsible for DHCP service.
Note: that the clock is reachable through its fixed link-local address
for diagnostic or re-configuration purposes. The link-local address is
169.254.0.100
The service light is located at the bottom right of the clock face.
1.
There is an active telnet configuration session in progress on the
clock.
The service light is located at the bottom right of the clock face.
1. Reboot the clock to verify that it properly receives a DHCP address.
2. Verify that the SNTP server configuration is valid as the service light
will also be illuminated after several missed updates. Refer to the
"Testing the Time Server Synchronization" section in Section 7: Telnet
Configurations
If the IP Address of each clock has not been recorded during installation,
it is suggested to follow this power cycle procedure.
1. Lift UP gently on the unit to free the keyholes at the rear of the clock
from the mounting hardware.
2. Disconnect the network cable from the clock in question and count to
five.
3. Replace the network cable and watch the face of the Inova Digital
Clock.
It will display its IP address as it boots.
No Time Server/Time Server down
Refer to the FAQ at
Table 6: Troubleshooting OnTime Digital Clock
www.buyinova.com
Solution
www.buyinova.com
under the support tab.