Problem
"Service" Indicator On.
Problem
Salt Level Too Low.
Possible Cause
Low salt level in pool water.
Cell requires cleaning.
Cell not working properly after cleaning
DC power cord not properly connected to the cell.
Flow/Temp/Salinity Sensor not plugged in.
Water temperature too low
All the above have been checked and indicator light is
still on.
Possible Cause
Not enough salt added on start up.
Heavy Rainfall.
Leak in pool.
Dirty Flow/Temp/Salinity Sensor contacts
or faulty Flow Sensor.
Corrective Action
Test salinity. Add salt as described in Section 4.7.
Refer to Maintenance Procedure for acid wash
cleaning. See Section 6.4, Step 2.
Contact your authorized service representative.
Check connection. Check for dirt or corrosion
around DC cord contacts at Cell. Check Cell studs
for same.
Plug Flow/Temp/Salinity Sensor into connector on
power center printed circuit board. (Cycle Power).
Winterize your pool. See Section 6.6, Winterizing.
Contact your authorized service representative.
Corrective Action
Add salt to pool, 3.0 gpl to 3.5 gpl.
See Section 4.7.
Add salt to pool, 3.0 gpl to 3.5 gpl.
See Section 4.7.
Repair pool.
Remove and clean Flow/Temp/Salinity Sensor
contacts. Check Flow/Temp/Salinity Sensor cable
for damage. See Section 6.5. Verify salinity with
Myron "L" meter calibrated for NaCl, titration test
units, or other salt meters. Please be aware that salt
test strips have a large variance in readings
(400 - 800 ppm).