5. A 1/8 inch (0.32 cm) N.P.T. plugged
tapping, accessible for test gauge
connection, MUST be installed immediately
upstream of the gas supply connection to
the dryer.
6. The dryer MUST be disconnected from the
gas supply piping system during any
pressure testing of the gas supply piping
system at test pressures in excess of 1/2
psig (3.45 kPa).
7. The dryer MUST be isolated from the gas
supply piping system during any pressure
testing of the gas supply piping system at
test pressures equal to or less than
1/2 psig (3.45 kPa).

LOCATION OF YOUR DRYER

DO NOT INSTALL YOUR DRYER:
1. In an area exposed to dripping water or
outside weather conditions.
2. In an area where it will come in contact
with curtains, drapes, or anything that will
obstruct the flow of combustion and
ventilation air.
3. On carpet. Floor MUST be solid with a
maximum slope of 1 inch (2.54 cm).
INSTALLATION IN RECESS OR CLOSET
1. A dryer installed in a bedroom, bathroom,
recess or closet, MUST be exhausted
outdoors.
2. No other fuel burning appliance shall be
installed in the same closet as the Gas dryer.
3. Your dryer needs the space around it for
proper ventilation.
DO NOT install your dryer in a closet with
a solid door.
4. A minimum of 120 square inches (774.2
square cm) of opening, equally divided at
the top and bottom of the door, is required.
Air openings are required to be unobstructed
when a door is installed. A louvered door
with equivalent air openings for the full
length of the door is acceptable.
MINIMUM INSTALLATION CLEARANCES -
Inches (cm)
SIDES
REAR
Alcove 0 (0 cm) 0 (0 cm)
Closet
0 (0 cm) 0 (0 cm)
Closet door ventilation required: 2 louvered
openings each 60 square inches (387 square
centimeters) — 3 inches (7.6 cm) from bottom
and top of door.
This dryer MUST be exhausted outdoors.
5. The following illustrations show minimum
clearance dimensions for proper operation
in a recess or closet installation.
NOTE: Under counter and stack models - 0 inches (0 cm) for sides, rear,
and top.
TOP FRONT
1 (2.54 cm)
If an under counter* installation is desired, the dryer MUST have a top sheet
kit installed, P/N 131629100. Kit is available from an authorized parts
distributor.
CLOSET DOOR
CLOSET DOOR
CLOSET DOOR
CLOSET DOOR
CLOSET DOOR
0" (0 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)
15" (38.1 cm)
15" (38.1 cm)
15" (38.1 cm)
15" (38.1 cm)
15" (38.1 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)
UNDER COUNTER INSTALLATION
*Custom-sized countertop is required.
5
60 SQ. IN.
60 SQ. IN.
60 SQ. IN.
60 SQ. IN.
60 SQ. IN.
(387.1 SQ. CM)
(387.1 SQ. CM)
(387.1 SQ. CM)
(387.1 SQ. CM)
(387.1 SQ. CM)
60 SQ. IN.
60 SQ. IN.
60 SQ. IN.
60 SQ. IN.
60 SQ. IN.
(387.1 SQ. CM)
(387.1 SQ. CM)
(387.1 SQ. CM)
(387.1 SQ. CM)
(387.1 SQ. CM)
1" (2.54 cm)
1" (2.54 cm)
1" (2.54 cm)
1" (2.54 cm)
1" (2.54 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)
1" (2.54 cm)
1" (2.54 cm)
1" (2.54 cm)
1" (2.54 cm)
1" (2.54 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)