IR Code (NEC Format)

How to connect
How to connect
G Connect your wired remote control to the Remote port on the Monitor.
Set the CONTROL LOCK to 'ON' on the Monitor back panel to operate Monitor with wired remote control.
Remote Control IR Code (NEC Format)
Remote Control IR Code (NEC Format)
G Output waveform
Single pulse, modulated with 37.917KHz signal at 455KHz
T
C
T1
G Configuration of frame
1st frame
Lead
Low
code
custom code
C0
C1 C2 C3 C4 C5 C6 C7 C0 C1 C2 C3 C4 C5 C6 C7 D0 D1 D2 D3 D4 D5 D6 D7 D0 D1 D2 D3 D4 D5 D6 D7
Repeat frame
Repeat code
G Lead code
9 ms
G Repeat code
9 ms
G Bit description
Bit "0"
0.56 ms
1.12 ms
G Frame interval : Tf
The waveform is transmitted as long as a key is depressed.
Tf
Carrier frequency
F
= 1/T
= f
/12
CAR
C
OSC
Duty ratio = T1/T
= 1/3
C
High
custom code
T
f
4.5 ms
0.55 ms
2.25 ms
Bit "1"
Tf
Tf=108ms @455KHz
Data code
Data code
0.56 ms
2.24 ms