Electrical Connection - GE Profile UPSE810 Use And Installation Manual

Profile dryers
Table of Contents

Advertisement

Minimum Clearance Other Than Alcove or Closet Installation
Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and 1 in. rear.
Consideration must be given to provide adequate clearance for installation and service.
PREPARING FOR INSTALLATION
1
OF NEW DRYER
EXTERNAL
DUCT
OPENING
DUCT TAPE OR
DUCT CLAMP
4" METAL DUCT
DUCT TAPE OR
DUCT CLAMP
TIP: Install your dryer before installing your washer.
This will allow better access when installing dryer exhaust.
REMOVING LINT FROM WALL EXHAUST
OPENING
INTERNAL DUCT
OPENING
WALL
CHECK THAT EXHAUST
HOOD DAMPER OPENS
AND CLOSES FREELY.
TILT THE DRYER SIDEWAYS
AND REMOVE THE FOAM
SHIPPING PADS BY PULLING
AT THE SIDES AND BREAKING
THEM AWAY FROM THE DRYER
LEGS. BE SURE TO REMOVE
ALL OF THE FOAM PIECES
AROUND THE LEGS.
6

ELECTRICAL CONNECTION

2
INFORMATION
WARNING - TO REDUCE THE RISK OF
FIRE, ELECTRICAL SHOCK AND PERSONAL
INJURY:
• DO NOT USE AN EXTENSION CORD OR AN
ADAPTER PLUG WITH THIS APPLIANCE.
Dryer must be electrically grounded in accordance
with local codes and ordinances. Installation must be
in accordance with the current CSA C22.1 Canadian
Electrical code part 1. Improper connection of the
equipment-grounding conductor can result in an
electric shock. Check with a qualified electrician or
service representative or personnel if you are in
doubt as to whether the appliance is properly
grounded.
Do not modify the plug provided with the appliance: if
it will not fit the outlet, have a proper outlet installed
by a qualified electrician.
ELECTRICAL REQUIREMENTS
This dryer must be connected to an individual branch
circuit protected by the required time-delay fuses or circuit
breakers. The power supply must be 120/240 volts. 60Hz
circuit with the wall receptacle as shown below.
G
Y
X
W
TYPICAL 30 AMP
RECEPTACLE FOR DRYER
The power supply must be protected with 30 Amp fuses or
breakers. It must be well grounded and conform to local
codes.
GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of
malfunction or breakdown, grounding will reduce the risk
of electric shock by providing a path of least resistance for
electric current. This appliance is equipped with a cord
having an equipment-grounding conductor and a
grounding plug. The plug must be plugged into an
appropriate outlet that is properly installed and grounded in
accordance with all local codes and ordinances.