16-24 ELECTRICAL SYSTEM
Battery
Terminal Voltage: 11.5 ∼ less than 12.8 V
Standard Charge 1.2 A × 5 ∼ 10 h (see following chart)
Quick Charge
If possible, do not quick charge. If quick charge is
done unavoidably, do standard charge later on.
Terminal Voltage: less than 11.5 V
Charging Method
○
Increase the charging voltage to a maximum voltage of
25 V if the battery will not accept current initially. Charge
for no more than 5 minutes at the increased voltage then
check if the battery is drawing current. If the battery
will accept current decrease the voltage and charge by
the standard charging method described on the battery
case. If the battery will not accept current after 5 min-
utes, replace the battery.
Battery [A]
Battery Charger [B]
Standard Value [C]
Current starts to flow [D]
•
Determine the battery condition after refresh charge.
○
Determine the condition of the battery left for 30 minutes
after completion of the charge by measuring the terminal
voltage according to the table below.
Criteria
12.8 V or higher
12.0 ∼ lower than 12.8 V
lower than 12.0 V
5 A × 1 h
CAUTION
1.2 A × 20 h
NOTE
Judgement
Good
Charge insufficient → Recharge
Unserviceable → Replace