LG GC-P207 Service Manual page 98

Sxs refrigerator
Table of Contents

Advertisement

TROUBLE DIAGNOSIS
CLAIMS.
3. Refrigeration
Residual
is weak.
frost.
No automatic defrosting.
Defrost does not return.
3) Cooling air leak.
Bad gasket adhestion
Door sag.
4) No cooling air circulation.
Faulty fan motor.
CAUSES AND CHECK POINTS.
Weak heat from heater.
Sheath Heater - rated.
Heater plate - rated.
Too short defrosting time.
Defrost Sensor.
- Faulty characteristics.
Seat-D(missing, location. thickness).
Structural fault.
Gasket gap.
Air inflow through the fan motor.
Bad insulation of case door.
Gap.
Bad attachment.
Contraction.
Bad adhesion.
Weak binding force at hinge.
Fan motor.
Self locked.
Wire is cut.
Bad terminal contact.
Door switch.
Faults.
Refrigerator and freezer switch reversed.
Button is not pressed.
- 98 -
Contact distance.
Button pressure.
Melted contact.
Contact.
Poor door
attachment.
Door liner
(dimension).
Contraction inner
liner.
Misalignment.
Bad terminal
connection.
P/U liquid leak.
HOW TO CHECK
I Check the fan motor
conduction: OK.
No conduction: NG.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gc-l207Gc-c207Gc-b207

Table of Contents