3. Cut the copper tubing close to the fitting.
4. Place the hex nut, back ferrule, and front ferrule
on the end of each tube as shown.
Front Ferrule
Back Ferrule
Hex Nut
– 37 –
Note: The following step will require the use of
a 9/16-in. wrench to hold the fitting body while
tightening each of the two 5/8-in. hex nuts.
5. Tighten using 2 wrenches, 1 to hold the fitting
body and 1 to tighten each hex nut.
Hex Nut
Fitting Body
Hex Nut