Hitachi RAK-18NH6AS Service Manual page 42

Room air conditioner
Hide thumbs Also See for RAK-18NH6AS:
Table of Contents

Advertisement

MODEL
PROM
REQUIRED VALUE
LABEL NAME
NO.
0A2
RTOTSA
157
WMAX_M
158
WMAX2_M
159
WSTD_M
15A
CMAX_M
15B
CSTD_M
15C
SDMAX_M
15D
SDRPM_M
15F
WMIN_M
160
CMINHI_M
161
CMIN_M
162
DMIN_M
163
PKOU_M
164
FZZY_GN_M
166
FZZYTM_M
172
SHIFTW_M
173
SFTSZW_M
175
SHIFTC_M
176
SHIFTD_M
17C
TEION_M
17D
TEIOF_M
182
FWSS_M
183
FWSOY_M
184
FWS_M
185
FWKAF_M
186
FWL_M
187
FWAH_M
188
FWH_M
18A
FWHH_M
18B
FCSOY_M
18C
FCS_M
18D
FCL_M
18E
FCAH_M
18F
FCH_M
190
FCHH_M
191
FDOY_M
192
FDS1_M
193
FDS2_M
Table 1 Fan speed by mode
Operation
Fan speed mode
mode
Heating
operation
Hi
Set fan speed "AUTO"
Hi
Set fan speed "Hi"
Cooling
operation
Hi
Set fan speed "AUTO"
Hi
Set fan speed "Hi"
Dehumidifying
operation
RAK-18NH6AS
RAK-18NH6A
REQUIRED VALUE
OF UNIT SIDE
OF UNIT SIDE
0°C
3500 min
-1
5300 min
3500 min
-1
5300 min
-1
2950 min
4000 min
-1
3000 min
3300 min
2400 min
-1
3250 min
2400 min
-1
2400 min
-1
2100 min
2100 min
800 min
-1
800 min
800 min
-1
800 min
1200 min
-1
1200 min
-1
1200 min
1200 min
550 min
-1
550 min
2
4 min
0 °C
0 °C
1.33 °C
1.33 °C
3.33 °C
3.33 °C
2 °C
9 °C
500 min
-1
500 min
-1
600 min
600 min
720 min
-1
720 min
800 min
-1
840 min
750 min
-1
840 min
-1
800 min
940 min
800 min
-1
940 min
1030 min
-1
1030 min
-1
550 min
550 min
-1
650 min
650 min
680 min
-1
740 min
700 min
-1
850 min
-1
700 min
890 min
-1
990 min
990 min
600 min
-1
600 min
660 min
-1
720 min
-1
660 min
720 min
Label name
Ultra Lo
FWSS_M
Sleep
FWSOY_M
Lo
FWS_M
Overload
FWKAF_M
Med
FWL_M
FWAH_M
FWH_M
Ultra Hi
FWHH_M
Sleep
FCSOY_M
Lo
FCS_M
Med
FCL_M
FCAH_M
FCH_M
Ultra Hi
FCHH_M
Sleep
FDOY_M
Lo 1
FDS1_M
Lo 2
FDS2_M
RAK-25NH6A
REQUIRED VALUE
OF UNIT SIDE
0°C
0°C
-1
5300 min
-1
-1
5300 min
-1
-1
-1
4000 min
-1
-1
3300 min
-1
3250 min
-1
-1
2400 min
-1
-1
-1
2100 min
-1
800 min
-1
-1
800 min
-1
-1
1200 min
-1
-1
-1
1200 min
-1
550 min
-1
2
1.5
4 min
4 min
0 °C
2 °C
0 °C
2 °C
1.33 °C
3.33 °C
2 °C
2 °C
9 °C
9 °C
-1
500 min
-1
-1
-1
600 min
-1
750 min
-1
-1
850 min
-1
-1
850 min
-1
-1
-1
1050 min
-1
1050 min
-1
-1
1170 min
-1
-1
-1
600 min
-1
-1
750 min
-1
870 min
-1
-1
980 min
-1
-1
-1
1030 min
-1
-1
1030 min
-1
600 min
-1
-1
750 min
-1
-1
-1
750 min
Table 2 Room temperature shift value
Operation mode
Heating operation
Cooling operation
Dehumidifying operation
– 47 –
RAK-35NH6A
RAK-50NH6A
REQUIRED VALUE
REQUIRED VALUE
OF UNIT SIDE
OF UNIT SIDE
0°C
5000 min
-1
5000 min
5000 min
-1
5000 min
-1
4000 min
4000 min
-1
4300 min
4300 min
3150 min
-1
3150 min
1550 min
-1
1550 min
-1
1400 min
1400 min
800 min
-1
800 min
-1
1200 min
-1
1200 min
-1
1200 min
1200 min
550 min
-1
1.5
4 min
2 °C
2 °C
1.33 °C
1.33 °C
3.33 °C
3.33 °C
2 °C
– °C
500 min
-1
-1
700 min
820 min
-1
920 min
-1
920 min
-1
-1
1120 min
1120 min
1120 min
-1
1120 min
1250 min
-1
1250 min
-1
680 min
-1
780 min
950 min
-1
1030 min
-1
1030 min
-1
1170 min
1170 min
-1
1200 min
1200 min
680 min
-1
780 min
-1
-1
780 min
Fan speed "AUTO, Hi, Med"
Fan speed "Lo, Sleep"
-1
-1
-1
-1
-1
-1
-1
800 min
-1
800 min
-1
-1
-1
550 min
-1
1.5
4 min
2 °C
2 °C
2 °C
– °C
500 min
-1
-1
700 min
820 min
-1
920 min
-1
920 min
-1
-1
-1
-1
-1
680 min
-1
780 min
950 min
-1
-1
-1
-1
680 min
-1
780 min
-1
-1
780 min
Shift value
SHIFTW_M
SFTSZW_M
SHIFTC_M
SHIFTD_M