Yamaha FZ1-N Service Manual page 419

Hide thumbs Also See for FZ1-N:
Table of Contents

Advertisement

Check each switch for continuity with the pocket tester. If the continuity reading is incorrect, check
the wiring connections and if necessary, replace the switch.
ECA14370
CAUTION:
Never insert the tester probes into the coupler terminal slots "1". Always insert the probes
from the opposite end of the coupler, taking care not to loosen or damage the leads.
Pocket tester
90890-03112
Analog pocket tester
YU-03112-C
NOTE:
• Before checking for continuity, set the pocket tester to "0" and to the "Ω × 1" range.
• When checking for continuity, switch back and forth between the switch positions a few times.
The switches and their terminal connections are illustrated as in the following example of the main
switch.
The switch positions "a" are shown in the far left column and the switch lead colors "b" are shown in
the top row.
The continuity (i. e., a closed circuit) between switch terminals at a given switch position is indication
by "
" There is continuity between red, brown/blue, and brown/red when the switch is set to
"ON" and between red and brown/red when the switch is set to "
ELECTRICAL COMPONENTS
8-95
".