Pump - GE Profile WPDH8800J Technical Service Manual

Front load washer
Table of Contents

Advertisement

To remove the water valve:
1.
Remove the top panel. (See
2. Disconnect the black and blue wires and the
orange wire from the cold water (C) solenoid.
3. Disconnect the 2 blue wires and the brown wire
from the hot water (H) solenoid.
4. Disconnect the valve outlet hose:
Note: The valve outlet hose is diffi cult to remove.
a. Squeeze the clamp and slide it back.
b. Carefully break the hose loose by inserting a
small fl at blade screwdriver under the hose
to break the seal.
c. Remove the hose.
Outlet Hose
5. Remove the single (6-mm) hex-head screw that
holds the valve to the cabinet.
6. Move the valve horizontally towards the hot
indicator stamped on the back of the washer.
.)
Top Panel
Cold Water
Hot Water

Pump

The pump consists of a 120-VAC, 60-Hz motor,
impeller, impeller housing, and a removable strainer
that helps prevent foreign objects from entering the
pump impeller and drain outlet.
The pump runs whenever the washer is in the
spin function of a cycle.
The pump runs if the water level control
overfl ow switch is closed and the washer is
plugged in. (Overfl ow protection)
The pump is capable of eliminating 17 gallons
(64 liters) per minute.
Recommended minimum standpipe diameter is
1
/
inches.
1
4
Standpipe maximum height is 96 inches,
measured from the fl oor at the washer location.
The pump motor has an approximate resistance
value of 10.6 Ω.
Operation of the pump can be checked by using
service test mode t08. (See
Specifi c failures associated with the pump can
initiate error code E8. (See
– 34 –
.)
Service Test Mode
.)
Service Test Mode
(Continued Next Page)

Hide quick links:

Advertisement

Table of Contents
loading