Mitsubishi Electric PEHD-P1.6EAH Technical & Service Manual page 33

Split-type, heat pump air conditioners
Table of Contents

Advertisement

4. STANDARD OPERATION DATA
Heat pump type Rating Conditions (ISO T1)
With Electric heater
Service Ref.
Without Electric heater
Mode
Capacity
Input
With Electric heater
Indoor unit
Service Ref.
Without Electric heater
Phase, Hz
Volts
Amperes
Outdoor unit Service Ref.
Phase, Hz
Volts
Amperes
Discharge pressure
Suction pressure
Discharge temperature
Condensing temperature
Suction temperature
Ref. pipe length
Intake air temperature
Discharge air temperature
Intake air temperature
SHF
BF
The unit of pressure has been changed to Mpa based on international SI system.
The conversion factor is : 1 (Mpa) = 10.2 (kgf/cm
PEHD-P1.6EAH
PEAD-P1.6EA
Cooling
W
4,500
kW
1.75
PEHD-P1.6EAH
PEAD-P1.6EA
1 , 50
V
240
A
0.55
PUH-P1.6VGA/YGA
1/3 , 50
V
240/415
A
7.43/2.67
MPa
2.02
(kgf/F)
(20.6)
MPa
0.50
(kgf/F)
(5.1)
°C
78.5
°C
52.4
°C
8.1
m
5
°C
D.B.
27
°C
W.B.
19
°C
D.B.
14.0
°C
D.B.
35
°C
W.B.
24
0.72
0.21
2
)
PEHD-P2EAH
PEAD-P2EA
Heating
Cooling
4,900
5,550
1.80
2.44
PEHD-P2EAH
PEAD-P2EA
1 , 50
240
0.55
0.63
PUH-P2VGA/YGA
1/3 , 50
240/415
7.43/2.86
10.39/3.88
2.02
2.35
(20.6)
(24.0)
0.43
0.51
(4.4)
(5.2)
76.9
85.3
55.2
-0.3
7.0
5
5
20
27
15
19
38.1
13.6
7
35
6
24
0.74
0.19
PEHD-P2.5EAH
PEAD-P2EA
Heating
Cooling
6,150
6,700
2.22
2.68
PEHD-P2.5EAH
PEAD-P2EA
1 , 50
240
0.63
0.72
PUH-P2.5VGA
1/3 , 50
240/415
9.36/4.02
11.27/4.11
10.32/4.03
2.37
2.16
(24.2)
(22.0)
0.41
0.52
(4.2)
(5.3)
83.2
78.5
49.6
-1.2
8.3
5
5
20
27
15
19
39.6
13.8
7
35
6
24
0.71
0.19
Heating
7,200
2.45
0.72
/YGA
1
1
2.14
(21.8)
0.40
(4.1)
76.1
-1.3
5
20
15
39.1
7
6
32