CDA RV921 Manual For Installation, Use And Maintenance page 35

Range cooker
Table of Contents

Advertisement

2.LPG
Remove the gas control knob and turn
the adjustment screw at the side of
the valve shaft fully clockwise.
Once the above is complete, refit the
knob and verify that the burner flame
is stable (the flame must not extinguish
when turning the control knob rapidly between maximum and
minimum position). Leave the control knob at the minimum position
for one minute to check the flame failure device function. The flame
should not extinguish. Repeat this process for all hob burner controls.
Final installation checks
1. Check that all connections are gas tight using appropriate
methods and that the flexible gas hose is positioned
correctly, hanging freely, is not kinked or trapped and is not
in contact with any sharp edges including unfinished cabinet
materials.
2. Check that the supply pressure is correct for the type of gas
being used (Natural Gas 20mbar, Butane 28-30mbar,
Propane 37mbar).
3. Check the correct functioning of all burners at nominal and
reduced rates.
fig.21
35

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rv911

Table of Contents