FACTORY SETTINGS
User Access Code:
Alarm Duration:
Hardwired Siren:
Zone Operating Mode:
Part-Arm:
Instant/Delay:
Entry/Exit Delay:
Entry/Exit Warning Tone:
Zone Lockout:
Jamming Detection:
RESET FACTORY SETTINGS
1. Press
,
User Access Code
This puts the system into Test Mode.
2. Undo the Control Panel cover fixing screws and
open the cover.
3. Remove the DC power jack, then remove and
disconnect one of the back-up batteries.
4. Set jumper link P1 to the ON position.
Jumper
Link
5. Reconnect the power supply jack.
6. The Control Panel will now reset itself with all factory
settings.
The Control Panel will beep and the zone 6 LED will
illuminate when the factory settings are restored to
memory.
Press
to clear the switch off the illuminated LED.
7. Reconnect and replace the back-up battery.
8. Reset jumper link P1 into the OFF position.
9. Close the Control Panel cover and refit the fixing
screws.
10. Press
to return to Standby.
22
1 2 3 4
3 minutes
Equal to Alarm Duration
Intruder (all zones)
Zones 1-4: Enabled
Zones 5-6: Disabled
Zone 1:
Delay
Zones 2-6: Instant
30 seconds
On
On
Off
,
OFF
ON
PROGRAMMING
INSTRUCTIONS
With the system in Standby (i.e. with the Power LED
ON).
Note: To get to Standby Mode simply press
repeatedly until only the POWER LED is illuminated.
Press
,
User Access Code
The Arm and Part-Arm LEDs will illuminate and all
Zone, Fire and tamper LEDs will flash.
The system is now in Program Mode
Note: After programming all required functions
press
to leave Program Mode and return to
Standby.
USER ACCESS CODE
This allows the 4 digit User Access code to be changed
to your own unique code which only you and other
system users should be aware off.
Default setting: 1 2 3 4
To change the setting press
Zone LEDs 1-4 will illuminate.
Enter the new 4 digit User Access Code. As each
digit is entered, an illuminated zone LED will be
turned OFF.
Press
to save the new setting and exit to
Program Mode, or
Press
to exit without saving.
SYSTEM HOUSE CODE
This enables the system house code of the Control
Panel to be configured.
Press
,
The current House Code setting will be displayed on
the status LEDs with an illuminated LED indicating a
setting of "1" in the House Code and LEDs which are
OFF indicating a "0".
,
,
Need help?
Do you have a question about the SA3 and is the answer not in the manual?