Download  Print this page

RealFyre G10-24/30 Owner's Manual

Hide thumbs

Advertisement

Burner Systems:
G10-24/30(P)
G10-24/30-12(M)(P)
G10-24/30-15(M)(P)
G10-24/30-01V(P)
For outdoor stainless steel models;
add (-SS) to end of model #
INSTALLER: Leave this manual with the appliance
CONSUMER: Retain this manual for future reference
Installation and service must be performed
by a qualifi ed professional installer, service
agency, or the gas supplier.
WARNING: If the information in this
manual is not followed exactly, a fi re or
explosion may result, causing property
damage, personal injury, or loss of life.
Do not store or use gasoline or other
fl ammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
• Open a window.
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier,
call the fi re department.
It is imperative that you maintain
your unvented gas appliance by
having it cleaned and serviced
regularly. See pages 11, 23 & 24
for details.
ROBERT H. PETERSON CO. • 14724 East Proctor Avenue, City of Industry, CA 91746
REV 8-1405271045
G10-24/30 SERIES UNVENTED GAS LOG SETS
CHAS-(24,30) Charred Aged Split Oak
CHFR-(24,30) Charred Frontier Oak
Important
Read these instructions carefully and completely
before starting installation of the burner system.
This appliance may be installed in an
a f t e r m a r k e t , p e r m a n e n t l y l o c a t e d ,
manufactured (mobile) home where not
prohibited by local codes.
This appliance is only for use with the type of
gas indicated on the rating plate. This appliance
is not convertible for use with other gasses.
This is an UNVENTED gas-fired heater. It
uses air (oxygen) from the room in which it is
installed. Provisions for adequate combustion
and ventilation air MUST be provided. See
section entitled VENTILATION AND CONFINED
SPACE INFORMATION.
This appliance is designed as an attended
appliance. Adults must be present when the unit
is operating. Do not leave this unit burning when
unattended or while anyone is sleeping.
Installation, service, and the provisions for combustion
and ventilation air MUST conform with local codes
and with the National Fuel Gas Code, ANSI Z223.1/
NFPA 54, or the CSA B149.1, Natural Gas And
Propane Installation Code.
1
OWNER'S
MANUAL
DESIGN CERTIFIED
to standards:
Unvented Room Heater
ANSI Z21.11.2b-2010
and
Vented Decorative Appliance
ANSI Z21.60b-2004
Log Sets:
CHT-(24,30) Charred Trail Oak
254-L-04-5
L-F2-070

Advertisement

Table of Contents

   Related Manuals for RealFyre G10-24/30

   Summary of Contents for RealFyre G10-24/30

  • Page 1 (-SS) to end of model # CHT-(24,30) Charred Trail Oak CHAS-(24,30) Charred Aged Split Oak CHFR-(24,30) Charred Frontier Oak G10-24/30 SERIES UNVENTED GAS LOG SETS Important INSTALLER: Leave this manual with the appliance Read these instructions carefully and completely CONSUMER: Retain this manual for future reference before starting installation of the burner system.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SPECIFICATIONS AND REQUIREMENTS IMPORTANT SAFETY INFORMATION VENTILATION AND CONFINED SPACE SAFETY INFORMATION MINIMUM CLEARANCES TO COMBUSTIBLES PRE-INSTALLATION AND FIREPLACE PREPARATION SAFETY INSTALLATION SAFETY INFORMATION INSTALLATION SAFETY GUIDELINES OPERATIONAL SAFETY INFORMATION CLEANING AND SERVICING IMPORTANT INFORMATION LOGS - PARTS LIST BURNER PARTS LIST FOR MANUAL VALVE BURNER PARTS LIST FOR SERIES 12 VALVE BURNER PARTS FOR SERIES 15 VALVE...
  • Page 3: Specifications And Requirements

    SPECIFICATIONS AND REQUIREMENTS WARNING: This appliance is for installation only in a: 1. Solid-fuel-burning masonry or UL-127 factory-built fi replace, or 2. Listed ventless fi rebox enclosure. R e a r It has been designed certifi ed for these installations. w i d t h H e i g h t HEIGHT...
  • Page 4: Important Safety Information

    IMPORTANT SAFETY INFORMATION UNVENTED ROOM HEATER GENERAL SAFETY INFORMATION A. WARNING: CARBON MONOXIDE POISONING MAY LEAD TO DEATH. When used without fresh air, gas appliances may give off carbon monoxide, an odorless, colorless, poisonous gas. Early signs of carbon monoxide poisoning are similar to the fl u, with headaches, dizziness, and/or nausea.
  • Page 5: Ventilation And Confined Space Safety Information

    VENTILATION AND CONFINED SPACE SAFETY INFORMATION Your vent-free gas burner system SHALL NOT BE INSTALLED IN A CONFINED SPACE or unusually tight construction unless provisions are made for adequate combustion and ventilation air. • The National Fuel Gas Code, ANSI Z223.1/NFPA 54 defi nes a confi ned space as a space whose volume is less than 50 cu.
  • Page 6: Minimum Clearances To Combustibles

    MINIMUM CLEARANCES TO COMBUSTIBLES If the vent-free burner system is installed in a factory Because of these variables, we cannot guarantee that heat warping or discoloration will never occur. The built fi replace, follow the manufacturer’s guidelines for minimum clearances to combustibles. potential for heat warping or discoloration may exist no matter what item(s) you are burning in the fi...
  • Page 7 MINIMUM CLEARANCES TO COMBUSTIBLES (Cont.) IF YOU CANNOT MEET THESE MINIMUM CLEARANCES, YOU MUST OPERATE THE VENT-FREE GAS BURNER SYSTEM WITH THE CHIMNEY FLUE DAMPER OPEN. Mantel clearance with hood * Mantel clearance without hood * Standard Fireplace Hood with minimum 4" horizontal projection Fireplace hood with minimum 4"...
  • Page 8: Pre-installation And Fireplace Preparation Safety

    PRE-INSTALLATION AND FIREPLACE PREPARATION SAFETY CAUTION: Installation and repair must be done by a qualifi ed professional installer. Installer: Carefully read these instructions before installing this gas burner system. Be sure you understand all safety precautions and warnings contained in this manual. PRE-INSTALLATION AND FIREPLACE PREPARATION SAFETY GUIDELINES A.
  • Page 9: Installation Safety Information

    INSTALLATION SAFETY INFORMATION INSTALLATION SAFETY GUIDELINES A. Carefully inspect the burner and log cartons for shipping damage. If any parts are missing/damaged, call your dealer. Do not attempt to install the appliance unless all parts are in good condition. B. Correct installation of the glass or the ceramic refractory log set and proper placement and installation of the burner assembly, including ember placement and Lava Granule placement, are imperative to safe operation of your set.
  • Page 10: Operational Safety Information

    OPERATIONAL SAFETY INFORMATION OPERATING YOUR UNVENTED GAS APPLIANCE SAFELY AND CORRECTLY A. SOLID FUEL MUST NOT BE BURNED in a fi replace where this vent-free gas appliance is installed. B. GLASS DOORS MUST BE FULLY OPEN when this vent-free gas appliance is operating. This appliance MUST NOT BE ON if glass doors are closed, as it can lead to sooting, burner outages, and possibly explosion, causing damage or injury.
  • Page 11: Cleaning And Servicing Important Information

    OPERATIONAL SAFETY INFORMATION (Cont.) OPERATING YOUR UNVENTED GAS APPLIANCE SAFELY AND CORRECTLY N. This appliance is intended for supplemental heating, and is not to be used as a primary heating source. Water vapor produced by vent-free burner systems can create moisture problems in a home when operated for extended periods of time.
  • Page 12: Logs - Parts List

    LOGS - PARTS LIST Log sets are purchased and packaged separately. Styles and sizes will vary depending upon the log set ordered. WARNING: Failure to position these parts in accordance with these diagrams, or failure to use only parts specifi cally approved with this vent-free gas log set, may result in property damage or personal injury.
  • Page 13: Burner Parts List For Manual Valve

    BURNER PARTS LIST FOR MANUAL VALVE G10-24/30(P) To order replacement parts, contact your Real-Fyre® Dealer. Rear Standard model shown here. Burner system is also available Front in stainless steel. ITEM DESCRIPTION ITEM DESCRIPTION Grate assembly Main burner " Valve assembly (natural)
  • Page 14: Burner Parts List For Series 12 Valve

    BURNER PARTS LIST FOR SERIES 12 VALVE G10-24/30-12(M)(P) Remote kit with remote instructions included Rear To order replacement parts, contact your Real-Fyre® Dealer. Standard model shown here. Burner system is also available in stainless steel. Front ITEM DESCRIPTION ITEM DESCRIPTION...
  • Page 15: Burner Parts For Series 15 Valve

    BURNER PARTS FOR SERIES 15 VALVE G10-24/30-15(M)(P) Remote kit with remote instructions included To order replacement parts, contact your Real-Fyre® Front Dealer. Rear Standard model shown here. Burner system is also available in stainless steel. ITEM DESCRIPTION ITEM DESCRIPTION ODS pilot (natural)
  • Page 16: Burner Parts For Series 01v Valve

    BURNER PARTS FOR SERIES 01V VALVE G10-24/30-01V(P) To order replacement parts, contact your Real-Fyre® Dealer. Front Rear 9 volt battery AA battery compartment (at rear) compartment (on side) Standard model shown here. Burner system is also available in stainless steel.
  • Page 17: When Used As A Vented Decorative Appliance (per Ansi Z21.60b-2004

    WHEN USED AS A VENTED DECORATIVE APPLIANCE (PER ANSI Z21.60b-2004) This appliance is for installation in a solid fuel burning fi replace (masonry fi replace or manufactured fi replace) with a working fl ue and constructed of noncombustible material. These gas logs may be installed as vented decorative log sets in compliance with ANSI Z21.60b-2004 and National Fuel Gas Code, Section 6.6.
  • Page 18: Installation

    C. G10-24/30-15(M)(P) - Hold in control knob at PILOT (see Fig. 18-4). 18-1 D. G10-24/30-01V(P) - Set control to manual. Press O/I to I (see Fig. 18-5 ). Use a pen tip to activate the switch inside the hole as shown in Fig. 18-1.
  • Page 19: Installation: Checking Gas Pressure

    INSTALLATION: CHECKING GAS PRESSURE I M P O R T A N T Check the gas pressure with the vent-free gas log set burning and the control set to HIGH. The gas log set and its main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of psig.
  • Page 20: Installation: Granule, Ember And Log Placement

    INSTALLATION: GRANULE, EMBER AND LOG PLACEMENT LAVA GRANULE PLACEMENT Fig. 20-1 Lava granules are provided as an aesthetic enhancement to the G10 vent-free gas log set. Spread the lava granules on the fl oor of the fi rebox around the front and the sides of the vent-free gas log set (Fig. 20-1). BE SURE THAT NO GRANULES ENTER THE MAIN BURNER OR INTERFERE WITH THE BURNING OF THE LOG SET.
  • Page 21: Installation: Log Placement

    INSTALLATION: LOG PLACEMENT FIBER LOG PLACEMENT THE CERAMIC FIBER LOG SET IS FRAGILE! TAKE CARE TO WHEN HANDLING IT TO AVOID BREAKAGE. ONLY LIFT LOG SET USING THE LOG SET BRACKETS The unitized ceramic fi ber log set has been designed with notches on the bottom front and rear logs ensuring positive placement and restricting any movement from side to side.
  • Page 22 INSTALLATION: LOG PLACEMENT (Cont.) REFRACTORY LOG PLACEMENT (cont.) 3. Position the top center log #5 on the top of the intermediate logs. Locate the top log by placing it into the slots of the intermediate logs (see Fig. 22-1). Fig. 22-1 4.
  • Page 23: Installation: Damper Clamp (if Applicable

    INSTALLATION: DAMPER CLAMP (IF APPLICABLE) The damper clamp with hex bolt (Fig. 23-1) is provided as a means to prevent full closure of the damper blade. The clamp is easily attached to most damper blades with pliers or a wrench, and must be permanently installed. The clamp is designed to prevent accidental closure of the damper when installed as illustrated (Fig.
  • Page 24: Cleaning And Servicing

    CLEANING AND SERVICING Only limited cleaning will be required under normal use of the unvented gas log set. TO CLEAN THE LOG SET 1. Remove the log set and embers. Use a vacuum cleaner to remove loose particles from all surfaces of the log set. Do not use cleaning fl uids. ODS pilot gas line connects here 2.
  • Page 25: Operating The Unvented Gas Log Set

    OPERATING THE UNVENTED GAS LOG SET Observe the fl ames. The main burner fl ames should be blue at the base and a combination of blue/yellow at the body and at the tips. They should be 5" to 8" above the logs, with the center fl...
  • Page 26: Lighting Instructions - Series 15 Valve

    LIGHTING INSTRUCTIONS - SERIES 15 VALVE FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly, a fi re or explosion may result, causing property damage, personal injury, or loss of life. Do not use this appliance if any part has been underwater. Immediately call for a qualifi ed professional service technician to inspect the appliance and to replace any part of the control system and any gas control that has been underwater.
  • Page 27: Lighting Instructions - Manual Valve

    LIGHTING INSTRUCTIONS - MANUAL VALVE FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fi re or explosion may result, causing property damage, personal injury, or loss of life. Do not use this appliance if any part has been underwater. Immediately call for a qualifi ed professional service technician to inspect the appliance and to replace any part of the control system and any gas control that has been underwater.
  • Page 28: Lighting Instructions - Series 12 Valve

    LIGHTING INSTRUCTIONS - SERIES 12 VALVE FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly, a fi re or explosion may result, causing property damage, personal injury, or loss of life. Do not use this appliance if any part has been underwater. Immediately call for a qualifi ed professional service technician to inspect the appliance and to replace any part of the control system and any gas control that has been underwater.
  • Page 29: Lighting Instructions - 01v(p) Valve

    LIGHTING INSTRUCTIONS - 01V(P) VALVE FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fi re or explosion may result, causing property damage, personal injury, or loss of life. Do not use this appliance if any part has been underwater. Immediately call for a qualifi ed professional service technician to inspect the appliance and to replace any part of the control system and any gas control that has been underwater.
  • Page 30: Notes Page

    NOTES PAGE Please use this page to record any information that you may want to have at hand.
  • Page 31: Troubleshooting

    TROUBLESHOOTING • ONLY A QUALIFIED PROFESSIONAL SERVICE PERSON SHOULD SERVICE AND REPAIR THIS APPLIANCE. • TURN OFF UNIT AND ALLOW TO COOL BEFORE TROUBLESHOOTING BURNER SHUTTING DOWN DURING OPERATION POSSIBLE CAUSE SOLUTIONS A. Insufficient or excessive gas A1. Check gas pressure (Read G.- I. of IMPORTANT PRE-INSTALLATION AND pressure FIREPLACE SAFETY INFORMATION section, &...
  • Page 32 TROUBLESHOOTING (Cont.) POSSIBLE CAUSE SOLUTIONS ODS PILOT WILL NOT LIGHT A. ODS pilot fl ame lifting off thermocouple/generator A. Check gas pressure (see Section 1, A1 of this table). B. Piezo spark not lighting ODS pilot B. Check to make sure piezo is sparking when pressing / turning ignitor.
  • Page 33 TROUBLESHOOTING (Cont.) POSSIBLE CAUSE SOLUTIONS SOOTING A. Low gas pressure A. Check gas pressure (see Section 1, A1 of this table). B. Drafts in room B. Eliminate drafts by closing heating and air conditioning vents, returns, and outside air vents. Fans blowing directly into fi replace should be turned off when system is operating.
  • Page 34: Warranty

    WARRANTY PETERSON VENT-FREE DECORATIVE GAS APPLIANCE LIMITED WARRANTY ® Robert H. Peterson Co. ("RHP") warrants your Real Fyre vent-free decorative gas appliance to be free from defects in material and workmanship. Peterson vent-free ceramic refractory gas logs are warranted for as long as you own them (lifetime). Peterson vent-free burner component parts, except valves, ODS pilots, and controls, are warranted for TEN (10) YEARS.

Comments to this Manuals

Symbols: 0
Latest comments: