MODELS 165F AND 167F
FAN FORCED WALL HEATERS
FINISH ASSEMBLIES
FOR USE WITH BROAN MODEL 171H ROUGH-IN HOUSING
READ AND SAVE THESE INSTRUCTIONS

IMPORTANT INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE
INSTALLING OR USING THIS HEATER.
To reduce the risk of fire, electric shock, or injury to persons, observe
the following:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
5. This heater is hot when in use. To avoid burns, do not let bare skin
touch hot surfaces. Keep combustible materials, such as furniture,
pillows, bedding, papers, clothes, etc. and curtains at least 3 feet (0.9
m) from the front of the heater.
6. Extreme caution is necessary when any heater is used by or near
children or invalids and whenever the heater is left operating and
unattended.
PLANNING
This wall heater finish assembly is intended for installation into a
Broan Model 171H rough-in housing — after the wall has been
completed.
The heater can be operated using the Broan Model 86 Line-
Voltage Thermostat from a wall location or the Broan Model 83
Integral Thermostat installed into heater. Purchase the control
separately.
The table below lists the ratings for each model.
MODELS VOLTS
AMPS
165F
120
4.17
240
2.08
208
1.8
240
3.13/6.25
167F
208
2.71/5.41
BOLD ratings are factory wired. See "OPTIONAL WIRING
CONVERSIONS" section for wattage and voltage conversion
instructions.
WATTS
BTU/HR
500
1707
500
1707
375
1280
750/1500
2560/5120
563/1125
1922/3840
7. Do not operate any heater after it malfunctions. Disconnect
power at service panel and have heater inspected by a reputable
electrician before reusing.
8. Do not use outdoors.
9. To disconnect heater, turn controls to off, and turn off power to
heater circuit at main disconnect panel (or operate internal
disconnect switch, if provided).
10. Do not insert or allow foreign objects to enter any ventilation or
exhaust opening, as this may cause an electric shock or fire, or
damage the heater.
11. To prevent a possible fire, do not block air intakes or exhaust in
any manner.
12. A heater has hot and arcing or sparking parts inside. Do not use it
in areas where gasoline, paint, or flammable vapors or liquids are
used or stored.
13. Use this heater only as described in this manual. Any other use
not recommended by the manufacturer may cause fire, electric
shock, or injury to persons.
14. Install heater at least 6 inches from floor or any adjacent wall.
15. To avoid electrical shock: Do not install unit in a tub or shower
enclosure or any location where it may come in contact with water.
Never place a switch where it can be reached from a tub or shower.
16. This product may ONLY be installed horizontally in a wall. Do not
mount in any other position.
17. Do not connect heater to dimmer switch or speed control.
18. This product must be grounded.
SAVE THESE INSTRUCTIONS
Follow these basic steps when installing this heater:
• Remove the housing mask.
• Fasten finish assembly inside housing.
• Plug assembly in.
• Attach grille.
DRYWALL
GRILLE
1
WALL
STUD
HEATER
HEATER
HOUSING
HOUSING
POWER
CABLE

Advertisement

Table of Contents
loading

Summary of Contents for Broan 165F

  • Page 1: Important Instructions

    Follow these basic steps when installing this heater: • Remove the housing mask. This wall heater finish assembly is intended for installation into a Broan Model 171H rough-in housing — after the wall has been • Fasten finish assembly inside housing. completed.
  • Page 2: Installation

    If a wall-mounted control has been pre-wired, nothing else need be done. If a built-in thermostat is desired, purchase and insert the Broan Model 83 Integral Thermostat at this time. WIRING 2)Connect the two (2) white wires with insulated terminals to Installation work and electrical wiring must be done by each other.
  • Page 3 WIRING MODEL 167F OPTIONAL WIRING CONVERSION MODEL 167F MOTOR TERMINAL UNATTACHED BLACK WIRE 1. Conversion to full wattage. The heater will produce more heat and use more electricity if converted to full wattage. Connect the unattached black wire with the insulated terminal to motor terminal.
  • Page 4: Complete The Installation

    COMPLETE THE INSTALLATION 1. Attach grille. Fasten grille to heater with two (2) screws from parts bag. 2. Check operation. Turn on power at service entrance. Turn thermostat to its highest setting and make sure heating element and blower come on. Then turn it to its lowest setting and make sure element and blower shut off.
  • Page 5: Operation

    OPERATION Before using heater, make sure heater has been properly installed according to installation steps beginning with the "PLANNING" section on page 1.
  • Page 6: Maintenance

    MAINTENANCE The following maintenance and cleaning tasks can be per- formed by the user. All other servicing must be performed by an authorized technician If you have any questions, please consult with our customer service department at: 800-558-1711. THERMAL OVERLOAD PROTECTOR If heater fails to operate when thermostat is turned to its highest setting: Turn power off at service entrance.
  • Page 7: Warranty

    IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
  • Page 8: Service Parts

    Wire Tie (5 Required) 99150470 Screw, #8-18 x 3/8 Ph. Truss Hd. 99270757 Heating Element (Model 167F) 99270742 Heating Element (Model 165F) 93270619 Wire Clamp 97008682 Partition Plate Assembly Always order replacement parts by part number - NOT key number. 99045021A...