Fujitsu ETERNUS DX200F Operation Manual page 24

All flash array
Hide thumbs Also See for ETERNUS DX200F:
Table of Contents

Advertisement

Chapter 2
Basic Operation
2.2
Using the FUNCTION Button
1
Remove the flange cover of the ETERNUS DX.
2
Change the status of the ETERNUS DX to maintenance status.
Use the pin to push down the FUNCTION button for three seconds.
The ETERNUS DX is in maintenance status when the MAINTENANCE LED is green.
3
Use the FUNCTION button to change settings.
Switching the Master CM to the other controller
Use the pin to push down the FUNCTION button twice within three seconds.
The MASTER LED for the controller that is set as the Master CM is green.
Restoring the factory default settings of the LAN ports
Use the pin to push down the FUNCTION button three times within three seconds.
After the default settings of the LAN ports are restored, the MAINTENANCE LED blinks green for a few
seconds.
4
Release maintenance status.
Use the pin to push down the FUNCTION button for three seconds.
The MAINTENANCE LED turns off, which indicates that the ETERNUS DX is no longer in maintenance sta-
tus.
5
Attach the flange cover.
24
FUJITSU Storage ETERNUS DX200F All Flash Array Operation Guide (Basic)
Copyright 2014 FUJITSU LIMITED