Uneven Bridge Thickness - Ice-O-Matic ICE0250 Series Service And Installation Manual

The ice series cubers
Hide thumbs Also See for ICE0250 Series:
Table of Contents

Advertisement

ICE Series

Uneven Bridge Thickness

Make sure
supply water
temperature is
below 100°F
(38°C)
Check for water
leaking out of Purge
Drain
Dirty or
defective Purge
Valve
OK
Is water
running into
the bin?
NO
NO
Evaporator(s)
flooded? See
page E4 and
Check the suction
pressure, is it high or
low? See pageE1
Make sure the
system is charged
properly, recover the
charge and weigh in
the correct amount
TXV diagnosis.
Page C10
YES
Are the
YES
E5
NO
HIGH
LOW
OK
Refer to page
E3 and E4 for
Troubleshooting Trees
Problem in
water system,
see pages D1
and D2.
Serpentine coil
on back of
evaporator
could be
separated, see
page E4
Hot Gas Valve
could be
leaking, see
page E5