Connecting a PC

PC control of the TV

• When a programme is set, the TV can be controlled
from the PC using the RS-232C or IP. The input
signal (PC/video) can be selected, the volume can be
adjusted and various other adjustments and settings
can be made, enabling automatic programmed
playing.
• Use an RS-232C serial control cable (cross type), LAN
cable (commercially available) or wireless LAN USB
adapter for the connections.
NOTE
• This PC control should be used by a person who is
accustomed to using PCs.
Communication conditions for IP
LAN
(commercially available)
Connect to the TV with the following settings made for IP
on the PC.
IP protocol
Host IP address
Service
TCP port#
When you set your ID and password on the TV menu, you
need to enter them as soon as you connect to the TV.
NOTE
• The connection will be cut off when there has been no
communication for 3 minutes.
View setting
IP Control setup
1
Go to "HOME" > "TV Menu" > "Setup" > "View
setting" > "Network setup" > "IP Control setup".
2
[Control setting]
This function is set to enable IP Control.
3
[Device name setting]
You can set up the name of this TV for displaying
on external devices.
4
[Detail setting]
You can set up Login ID, Password and Control
port for using IP Control.
Communication conditions for RS-232C
RS-232C serial control cable (cross type)
(commercially available)
68
LC-6070UD1H_EN_book.indb 68
LC-6070UD1H_EN_book.indb 68
LAN cable
TCP/IP.
Set the IP address on the TV menu.
None (do not select Telnet or SSH).
Set a port number on the TV menu
(Control port).
Set the RS-232C communications settings on the PC
to match the TV's communications conditions. The TV's
communications settings are as follows:
Baud rate
9,600 bps
Data length
8 bits
Parity bit
None
Stop bit
1 bit
Flow control
None
Communication procedure
Send the control commands from the PC via the RS-
232C connector.
The TV operates according to the received command
and sends a response message to the PC.
Do not send multiple commands at the same time. Wait
until the PC receives the OK response before sending
the next command.
Command format
Eight ASCII codes +CR
C1 C2 C3 C4 P1 P2 P3 P4
Command 4-digits: Command. The text of four characters.
Parameter 4-digits: Parameter 0–9, blank, ?, minus
Return code (0DH): ?
Parameter
Input the parameter values, aligning left, and fill with
blank(s) for the remainder (be sure that four values are
input for the parameter).
When the input parameter is not within an adjustable
range, "ERR" returns (refer to "Response code format").
0
0
0
1
0
0
0
When "?" is input for some commands, the present
setting value responds.
?
?
Response code format
Normal response
O
K
Return code (0DH)
0
9
0
5
5
?
?
Problem response
(communication error or
incorrect command)
E
R
R
Return code (0DH)
1/2/2014 8:57:30 AM