62
Hardware Maintenance Manual A40 Type 6840 A40P Type 6841 A40i Type 2271: IBM NetVista Computer
POST Error Code
190
Chassis intrusion detector was cleared. This
is information only, no action required. If
this code does not clear:
1XX
Not listed above
201, 20X
Memory data error
225
229
External cache test error
262
POST detected a base memory or extended
memory type error
301
303
With an 8603 error
303
With no 8603 error
3XX
Not listed above
5XX
601
602
FRU/Action
1. System Board
1. System Board
1. Run Enhanced Diagnostics Memory
Test
2. Memory Module
3. System Board
1. Unsupported Memory
1. L2 Cache Memory
2. System Board
1. Run Setup. Check System Summary
menu for memory. (See "Setup Utility
program" on page 7.)
2. Run the Extended Memory Diagnostic
tests.
1. Keyboard
2. Keyboard Cable
3. System Board
1. Mouse
2. Keyboard
3. Keyboard Cable
4. System Board
1. Keyboard
2. Keyboard Cable
3. System Board
1. Keyboard
2. Keyboard Cable
3. System Board
1. Video Adapter (if installed)
2. System Board
1. Diskette Drive A
2. Diskette Drive Cable
3. System Board
4. Riser card
1. Bad Diskette?
2. Verify Diskette and retry