Cannot Run Workflows If The Ps1 Environment Variable Is Altered; Other Common Problems - IBM 51 Troubleshooting Manual

Ibm troubleshooting guide
Table of Contents

Advertisement

Cannot run workflows if the PS1 environment variable is
altered
Cause
When running scriptlets in Tivoli Intelligent Orchestrator, the system will expect
that the command prompt ends in $ or #. The PS1 environment variable governs
what your prompt looks like. If you change this variable on your managed-to or
managed-from system, you might run into problems running workflows.
For example, on most UNIX systems, when you are logged in as tioadmin, by
default, you see the following command prompt:
$
If you change the PS1 variable for tioadmin to be tioadmin>, then you will see the
following as the command prompt:
tioadmin>
Solution
To be able to run scriptlets in Tivoli Intelligent Orchestrator, ensure that the
command prompt ends in $ or #.
Here are examples of acceptable command prompts:
command$
$
#
command#
For more information on troubleshooting workflows, refer to the Developing
automation packages section in the Tivoli Intelligent Orchestrator information center.

Other common problems

This section includes troubleshooting scenarios for the following problems:
v "On Windows, Tivoli Intelligent Orchestrator does not start" on page 69
v "Problems occur when administering Tivoli Intelligent Orchestrator from the
v "Incorrect SOAP parameters generate detailed Java exception messages" on page
v "XML import does not work properly" on page 70
v "DB2 Universal Database does not work properly with terminal server" on page
v "On UNIX, Tivoli Intelligent Orchestrator logs fill up the file system" on page 71
v "On Windows 2000, the embedded messaging feature does not work" on page
v "WebSphere Application Server on Linux remains paused when you try to stop
v "On Windows, the remote connection to the database hangs when the database
v "For languages other than English, the text in CSV reports imported in Microsoft
v "An error occurs if you use special characters to create a new user or security
68
Tivoli Intelligent Orchestrator Problem Determination and Troubleshooting Guide
Web interface while a local firewall is enabled" on page 69
70
71
71
the JMS pub sub broker" on page 72
server is on a multiprocessor machine" on page 72
Excel is garbled" on page 73