If FLASHPRO3 does not start correctly
FLASHPRO3 will not start correctly if the communication settings are wrong or if installation has not been
performed correctly.
When FLASHPRO3 starts, connection with the PG-FP3 is checked. If communication is not being performed
normally, the following dialog is displayed.
This dialog is displayed because:
1.
The cables are not correctly connected.
Correctly connect the cables. Especially, connect the RS-232C cable correctly because it is a straight
cable.
2.
The selected interface is wrong.
Check to see if the setting of the I/F SELECT switch matches the interface used.
3.
Setting of Connection Port is wrong.
If the setting of the Port is different from the Port actually being used for the host, set the correct port.
4.
A wrong communication rate is set.
The PG-FP3 operates at a communication (baud) rate of 9600 bps on starting if the RS-232C interface is
selected. If a wrong baud rate is set, correct the setting.
There is also a possibility that the communication settings for the RS-232C port are wrong. Also check the
RS-232C port. The correct communication setting is Data: 8 bits, Stop bit: 2 bits, Parity: None, Flow control:
None.
5.
Other cases
If all the above are okay but FLASHPRO3 will still not start, either FLASHPRO3 is not correctly installed or
the PG-FP3 is damaged. If FLASHPRO3 will not start after it is installed again, notify NEC.