Troubleshooting your KTD-405 keypad

This section provides information to help you diagnose and solve various problems that may arise while
configuring or using your GE Security product and offers technical support contacts in case you need
assistance. (See
Adhere to all installation guidelines while making connections, including those provided in section Chapter 2,
Installation
on page 7.
• I can't control the cameras or DMVRes.
This could be the result of a number of different causes. First, make sure that you are in zone mode
while trying to control cameras through a DVMRe.
Also try cycling the power on the DVMRe and keypad to see if a simple reset will correct the problem.
If neither of these acts solves the problem, check the wiring, verifying the following:
The correct type of wiring (STP or UTP) is being used for the different signals.
All wires are in good condition.
All cabling and pinout connections are made according to directions (observing polarity).
Equipment is properly terminated.
Cables are properly grounded.
Lastly, the cause of the problem could be incorrect wiring of dome inputs or incorrect zone addressing
(camera addressing starts at 0 in zone mode). The address of the camera has to be one less than the
input on the DVMRe. Readdress the cameras or move the coaxial connections up one input on the
DVMRe.
If none of these solutions corrects the problem, contact customer support.
• I cannot connect to a DVMRe.
If the DMVRe is a triplex, ensure that the hubs are set to triplex in the zone programming.
• I have lost control between keypads.
The keypad may be positioned incorrectly on the RS-422 control line with a switcher and data merger.
Refer to the keypad, switcher, and data merger installation instructions and correct wiring along
RS-422 control line. With the KTD-405 keypad, the units should be in line in the following order:
keypad, data merger, and switcher.
• Audio on KTD-405A keypads is unclear.
You probably have incorrectly set jumpers or a faulty KTD-336. Ensure that the attenuation jumpers
are set as described in
If a KTD-336 is present, ensure that its relays are not clicking. If they are, contact customer support.
• I cannot control the dome camera.
You may have poor voltage or resistance on the data line. If the wiring, addressing, and termination of
the camera and keypad are all correct, verify that the voltage along the RS-422 data line reads
approximately 1.5 VDC and that it drops when a command is sent. If it isn't, check the power line.
Also verify that the resistance across the RS-422 data line is between 95 and 125 ohms. If it isn't,
contact customer support.