Auto Setup For Windows 3.1, Windows 95, Windows 98 Or Windows Nt - IBM 21L4365 User Manual

18.1-inch tft lcd monitor
Table of Contents

Advertisement

Auto Setup for Windows 3.1, Windows 95, Windows 98 or Windows NT

If the monitor is in standby
mode (STANDBY ON), it
may automatically turn off while
you are waiting for it to warm up.
You can disable the Windows
energy saving feature by
clicking on the S
button and
TART
selecting S
, C
ETTINGS
ONTROL
P
, D
, S
S
ANEL
ISPLAY
CREEN
AVER
Make sure that the E
NERGY
SAVING FEATURES OF MONITOR
check boxes are either empty, or
that the features are set to at
least 20 minutes.
Your system may also have its
Power Saving utility enabled
through the Bios Setup Utility.
Refer to your system manual for
directions on disabling that bios
option.
The size and diversity of
the dot pattern varies with
the screen resolution.
Position the mouse pointer
at the bottom center of the
A
screen. This allows
UTO
S
to run properly
ETUP
1.
Turn on the monitor first; then the PC.
If the message CHECK SIGNAL CABLE is displayed, or if nothing is
displayed check:
that the video interface cable is connected properly.
the correct video adapter card is installed.
the correct supported display mode is selected for your PC.
.
2.
Wait approximately 15 minutes, until the monitor warms up.
3.
Drag the icon bar and tool bar, if they are displayed, to the bottom of the
screen.
4.
Insert the diskette labelled 'IBM Monitor Installation Disk' into the
diskette drive.
5.
Check the operating system installed on your PC and follow the
instructions from the table below.
Operating
System
Windows 3.1
Windows NT 3.5
Windows 95
Windows 98
Windows NT 4.0
6.
When the test pattern appears, press the OSD Enter button
bottom of the monitor to display the initial OSD menu.
7.
Use an Arrow button (
press the OSD Enter button
8.
Using an Arrow button (
Enter button
optimize the display settings with the provided test pattern.
The screen will dim, blink on and off several times, and you may notice
small changes to the test pattern.
(To abort the
A
9.
When finished, the OSD main menu returns. Press the Exit button
once to exit from the OSD.
Step1
Step2
Open
Select
P
ROGRAM
F
ILE
M
ANGER
Select
Select R
S
TART
-
+
) to select the
or
to access the function.
-
+
), select
or
. This activates the
A
UTO
function, press the
S
UTO
ETUP
Step3
Step4
Select
R
UN
Type
'A:\TESTPAT'
and press
ENTER
UN
icon
IMAGE LOCK
and press the OSD
AUTOMATIC
procedure, which will
S
ETUP
key.)
E
SC
at the
and
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents