Low Water Alarm Function - Honeywell CL25AE Owner's Manual

Portable evaporative air cooler
Hide thumbs Also See for CL25AE:
Table of Contents

Advertisement

USE & OPERATION
SWING / ION
To switch between the SWING, ION & SWING+ION modes.
Press the SWING button. The indicator light on 'S' will come
on and the louvers will begin to move from right to left
automatically. Manually adjust the horizontal louvers to
change vertical airflow. To turn on the ionizer function, press
the SWING/ION button again and the ionizer functions starts
when the indicator on 'I' comes on. Both functions can also be
activated by sequential pressing of this button.
TANK EMPTY
This LED will illuminate only when the water tank is
below the desired minimum level and the COOL function
is ON. Everytime the water tank goes below the mini-
mum level the LOW WATER ALARM function will
activate with the help of a low water sensor. You will hear 10 beeps and the TANK EMPTY
led indicator will flash continuously. At the same time the power to the pump inside the unit
will be cut off to protect the life of the pump.
To disengage the low water alarm function, turn off and unplug the unit from the power
outlet, and fill the tank with water above the minimum level.
To turn off the alarm function and continue to use it in FAN mode, turn off the unit and turn
the unit on. If COOL button is pressed again without filling the tank with water, low water
alarm will activate again.