Connect Vent

1. Using a 4" (102 mm) clamp, connect vent to exhaust outlet
in dryer. If connecting to existing vent, make sure the vent is
clean. The dryer vent must fit over the dryer exhaust outlet
and inside the exhaust hood. Make sure the vent is secured
to exhaust hood with a 4" (102 mm) clamp.
2. Move dryer into final position. Do not crush or kink vent,
and remove any excess flexible vent to improve airflow.
Make sure dryer is level.
20

Complete Installation

1. With dryer in final position, place level on top of the dryer, first
side to side; then front to back. If the dryer is not level, adjust
the legs of the dryer up or down until the dryer is level.
2. Plug in dryer or reconnect power.
3. Check dryer operation (some accumulated time may be on
the timer due to factory testing):
Close dryer door. Insert coins in slide and press slide in
slowly. (Operating time will accumulate per number of coins
and type of timing cam used.) Select the Whites
and Colors cycle and let the dryer run for at least five minutes.
NOTE: Dryer door must be closed for dryer to operate.
4. Open the dryer door. Check that the inside of the dryer is
warm. If the burner does not ignite and you can feel no heat
inside the dryer, wait for five minutes. Check that all supply
valve controls are in "ON" position and that the electrical cord
is plugged in. Repeat five-minute test.
5. If drying time is too long, make sure that the lint screen is
clean and that there are no obstacles to airflow in the dryer
vent system.
6. Restart the dryer and allow it to complete a full cycle to make
sure it is working properly.