Carrier Performance 59TP5A Series Product Data

Carrier Performance 59TP5A Series Product Data

Boost two-stage 4-way multipoise condensing gas furnace series 100

Advertisement

59TP5A
Performance™ Boost Two---Stage
4---Way Multipoise
Condensing Gas Furnace
Series 100
The 59TP5A Two- -stage Multipoise Performance™ Boost
Condensing Gas Furnace features two- -stage heating comfort along
with SEER- -boosting year- -round electrical efficiency. The
Comfort Heat TechnologyR two- -stage gas valve is at the heart of
the comfort provided by this furnace, along with the
electrically- -efficient basic ECM blower motor, and two- -speed
inducer motor. With an Annual Fuel Utilization Efficiency (AFUE)
of up to 96.7%, this Performance
provides exceptional savings when compared to a standard furnace.
This gas furnace also features 4- -way multipoise installation
flexibility, and is available in five model sizes. The 59TP5A can be
vented for direct vent/two- -pipe, ventilated combustion air, or
single- -pipe applications. All units meet California Air Quality
Management District emission requirements. All sizes are design
certified in Canada.
STANDARD FEATURES
S Comfort Heat TechnologyR two- -stage heating operation
S Quiet operation. Compare for yourself at HVACpartners.com
S High- -efficiency basic ECM multiple- -speed blower motor for
electrically efficient operation all year long in heating, cooling
and continuous fan operation
Product Data
A11263
Series two- -stage gas furnace
TM
S Humidistatt Control compatible; dehumidification input for
better comfort
S SmartEvap™ technology helps control humidity levels in the
home when used with a compatible humidity control system
S ComfortFan™ technology allows control of continuous fan
speed from a compatible thermostat
S Ideal height 35" (889 mm) cabinet: short enough for taller coils,
but still allows enough room for service
S Silicon Nitride Power Heat™ Hot Surface Igniter
S External Media Filter Cabinet included
S 4- -way multipoise design for upflow, downflow or horizontal
installation, with unique vent elbow and optional through- -
the- -cabinet downflow venting capability
S Self diagnostics
S Multi- -speed ECM blower motor, two- -speed inducer motor, and
two- -stage gas valve
S Adjustable blower speed for heating, cooling and continuous fan
S Aluminized- -steel primary heat exchanger
S Stainless- -steel condensing secondary heat exchanger
S Propane convertible (See Accessory list)
S Factory- -configured ready for upflow applications
S Fully- -insulated casing including blower section
S Convenient Electronic Air Cleaner and Humidifier connections
S Direct- -vent/sealed combustion, single- -pipe venting or
ventilated combustion air
S Installation flexibility: (sidewall or vertical vent)
S Residential installations may be eligible for consumer financing
through the Retail Credit Program

LIMITED WARRANTY*

S 10 year parts and lifetime heat exchanger limited warranty to the
original purchaser upon timely registration.
S Limited warranty period is five years for parts and twenty years
for the heat exchanger if not registered within 90 days of
installation.{
* For owner occupied, residential applications.
Jurisdictions where warranty benefits cannot be conditioned on registra-
{
tion will receive registered limited warranty benefits.
1

Advertisement

Table of Contents
loading

Summary of Contents for Carrier Performance 59TP5A Series

  • Page 1: Limited Warranty

    59TP5A Performance™ Boost Two---Stage 4---Way Multipoise Condensing Gas Furnace Series 100 Product Data S Humidistatt Control compatible; dehumidification input for better comfort S SmartEvap™ technology helps control humidity levels in the home when used with a compatible humidity control system S ComfortFan™...
  • Page 2: Specifications

    SPECIFICATIONS Heating Capacity and Efficiency 040-10 060-14 080-16 100-16 120-22 High Heat (BTUH) 40,000 60,000 80,000 100,000 120,000 Input Low Heat (BTUH) 26,000 39,000 52,000 65,000 78,000 High Heat (BTUH) 39,000 58,000 78,000 98,000 117,000 Output Low Heat (BTUH) 25,000 38,000 52,000 63,000...
  • Page 3: Model Number Nomenclature

    MODEL NUMBER NOMENCLATURE 1 - 2 7 - 9 11 - 12 15 - 16 Family Htg. Stages Tier Effy. Major Series Htg. Cap. Motor Width Voltage Minor Series Airflow 08 - 800 CFM Family 10 - 1000 CFM 12 - 1200 CFM S - Single Stage 14 - 1400 CFM T - Two Stage...
  • Page 4 Carrier Infinity Air Purifier - 16x25 (406x635 mm) GAPAAXCC1625-A08 Carrier Infinity Air Purifier - 20x25 (508x635 mm) GAPAAXCC2025-A08 Carrier Infinity Air Purifier Repl. Filter- 16x25 (406x635 mm) GAPACCCAR1625-A05 Carrier Infinity Air Purifier Repl. Filter- 20x25 (508x635 mm) GAPACCCAR1625-A05 EZ Flex Cabinet 16” (406 mm) EZXCABCC1016-A20 EZ Flex Cabinet 20”...
  • Page 5 AIR DELIVERY - - CFM (BOTTOM RETURN WITH FILTER) EXTERNAL STATIC PRESSURE (IN. W.C.) INPUT RETURN-AIR SPEED BTUH SUPPLY 5(Gry) 1120 1080 1030 4(Yel) 40000 SIDE/BOTTOM 3(Blu) 2(Org) 1(Red) 5(Gry) 1720 1670 1620 1565 1505 1440 1375 1295 1220 1135 4(Yel) 1325 1285...
  • Page 6 MAXIMUM EQUIVALENT VENT LENGTH - - FT. (M) NOTE: Maximum Equivalent Vent Length (MEVL) does NOT include elbows or terminations. Use Table 2 - Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application. Table 1 – Maximum Equivalent Vent Length - - Ft. (M) 0 to 4500 Ft.
  • Page 7 MAXIMUM EQUIVALENT VENT LENGTH - - FT. (M) Table 3 – Maximum Equivalent Vent Length - - Ft. (M) 4501 to 10,000 Ft. (0 to 1370 M) Altitude NOTE: Maximum Equivalent Vent Length (MEVL) does NOT include elbows or terminations. Use Table 2 - Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application.
  • Page 8 MAXIMUM ALLOWABLE EXPOSED VENT LENGTHS INSULATION TABLE - - FT. (M) Maximum Length of Uninsulated and Insulated Vent Pipe-Ft (M) No Insulation 3/8-in. (9.5 mm) 1/2-in. (12.7 mm) Winter Stage Pipe Pipe Diameter-in. (mm) Pipe Diameter-in. (mm) Pipe Diameter-in. (mm) Design Furnace Length in...
  • Page 9: Return Air Temperature

    RETURN AIR TEMPERATURE This furnace is designed for continuous return- -air minimum temperature of 60_F (15_C) db or intermittent operation down to 55_F (13_C) db such as when used with a night setback thermometer. Return- -air temperature must not exceed 80_F (27_C) db. Failure to follow these return air limits may affect reliability of heat exchangers, motors and controls.
  • Page 10 Carrier cased coil is used. It is combustion air to be drawn in through the outer pipe.
  • Page 11: Typical Wiring Schematic

    MEDIA FILTER CABINET 25-5/8" (651mm) 24-1/4” 23-5/8" (616mm) (600mm) Opening with Flanges Bent 23-1/8” 23-3/8” (588mm) (594mm) Opening Duct Side Furnace Side 23-3/4” (603mm) " Centerline Screw Slots (146mm) A11456A DIMENSIONS (IN. / MM) MEDIA FILTER CABINET SHIPPED WITH SIZES 040--- 08, 040--- 12, 060--- 08, 16 (406.4) 17 (432.8)
  • Page 12: Dimensional Drawing

    DIMENSIONAL DRAWING A11436 NOTE: Doors may vary by model. a. For 800 CFM--- 16--- in. (406 mm) round or 14 1/2 x 12--- in. (368 x 305 mm) rectangle. b. For 1200 CFM--- 20--- in. (508 mm) round or 14 1/2 x 19 1/2--- in. (368 x 495 mm) rectangle. c.
  • Page 13: Guide Specifications

    GUIDE SPECIFICATIONS General System Description Primary Heat Exchangers Furnish a ______________________ 4- -way multipoise gas- -fired Primary heat exchangers shall be 3- -Pass corrosion- -resistant condensing furnace for use with natural gas or propane (factory- - aluminized steel of fold- -and- -crimp sectional design and applied authorized conversion kit required for propane);...
  • Page 14 Catalog No: 59TP5A ---01PD Copyright 2011 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 09/11 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.