UNVENTED (VENT-FREE) UNiVERsal FiREBOX
OWNER's OPERaTiON aND iNsTallaTiON MaNUal
PFS
MODEls
36" See-Thru Heat-
UVC-sT
Circulating Firebox
UV-sT 36'' See-Thru Non-
Circulating Firebox
wARNING: If the information in this manual is not
followed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— wHAT To Do IF YoU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
For more information, visit www.fmiproducts.com
®
US
UVC-ST SHowN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UVC-ST 36 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for FMI UVC-ST 36

  • Page 1 UNVENTED (VENT-FREE) UNiVERsal FiREBOX OWNER’s OPERaTiON aND iNsTallaTiON MaNUal ® MODEls 36" See-Thru Heat- UVC-sT Circulating Firebox UV-sT 36'' See-Thru Non- Circulating Firebox UVC-ST SHowN wARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 2: Table Of Contents

    WARNING: Improper installation, adjustment, al- teration, service or maintenance can cause injury or property damage. Refer to this manual for correct in- stallation and operational procedures. For assistance or additional information consult a qualified installer, service agency or the gas supplier. WARNING: For use only with decorative type un- vented room heaters.
  • Page 3 saFETy Continued 1. This firebox shall not be installed in a wARNING: Do not use a blow- bedroom or bathroom. er insert, heat exchanger insert 2. Never install the firebox or other accessory not approved • in a recreational vehicle for use with this firebox.
  • Page 4: Local Codes

    If items are missing, inform heat shield. See Figure 19, page dealer where you bought firebox. 3. Check firebox for any shipping damage. If firebox is damaged call FMI PRODUCTS, LLC at 1-866-328-4537 for replacement parts before returning to dealer. PRODUCT FEaTUREs...
  • Page 5: Product Specifications

    PRODUCT sPECiFiCaTiONs " 24" 1/2" 5/8" " " 3" " " 4" " " 40" " " " " " 12" Figure 1 - Dual-Sided Firebox lOCaTiNg FiREBOX pLANNING Internal wall installation provides a discreet viewing option between two Plan where you will install the firebox. This will adjacent rooms or within an added wall save time and money later when you install to subdivide an oversize room.
  • Page 6: Air For Combustion And Ventilation

    aiR FOR COMBUsTiON aND VENTilaTiON Unusually Tight Construction wARNING: This heater shall The air that leaks around doors and windows not be installed in a room or may provide enough fresh air for combustion and ventilation. However, in buildings of un- space unless the required vol- usually tight construction, you must provide ume of indoor combustion air...
  • Page 7 aiR FOR COMBUsTiON aND VENTilaTiON Continued DETERMINING FRESH-AIR FLow 4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/ FoR FIREBox LoCATIoN Hr used. Determining if You Have a Confined or _______ Btu/Hr (maximum the space can Unconfined Space support) Use this work sheet to determine if you have...
  • Page 8: Installation

    aiR FOR COMBUsTiON aND VENTilaTiON Continued VENTILATIoN AIR Ventilation Air From outdoors Provide extra fresh air by using ventilation Ventilation Air From Inside Building grills or ducts. You must provide two perma- This fresh air would come from an adjoining nent openings: one within 12"...
  • Page 9 iNsTallaTiON Continued C. When firebox is installed on carpeting CAUTIoN: Log heaters in- or other combustible material, other stalled in this firebox create warm than wood flooring, the firebox should be installed on a metal or wood panel air currents. These currents move extending the full width and depth of the heat to wall surfaces next to fire- enclosure.
  • Page 10 iNsTallaTiON Continued Mantel Clearances for Built-In BUILT-IN FIREBox INSTALLATIoN Installation Built-in installation of this firebox involves If placing custom mantel above built-in fire- installing firebox into a framed-in enclosure. box, you must meet the minimum allowable This makes the front of firebox flush with clearance between mantel shelf and top of wall.
  • Page 11 iNsTallaTiON Continued 4. Install gas piping to firebox location. See wARNING: Use only non- Installing Gas Line and Connecting to Gas Supply in log set owner’s manual. combustible mortar or adhe- IMPORTANT: If installing blower accessory. sives when overlapping the front See Hard-Wiring Firebox, page 13.
  • Page 12 iNsTallaTiON Continued hand sides (see Figure 11). Remove the gas CAUTIoN: Do not use exces- line cover plate from the vent-free firebox’s sive force to remove the knock- outer surround at the location to be used. If a sediment trap is not incorporated as a part out.
  • Page 13 120 VAC supply connection are made at either end of the cabinet. Use of a blower can be detected and corrected. system other than those manufactured by FMI Do NoT USE opEN FLAME FoR PRODUCTS, LLC voids the warranty.
  • Page 14 iNsTallaTiON Continued cabinet for air to flow properly. Note: A 120V supply connection to the leads 5. Apply gentle force between hook and loop to the receptacle must be provided for use mounting strips to seat blower. with the optional blower kit whether installed 6.
  • Page 15 iNsTallaTiON Continued FIELD WIRE INCOMING 120V AC BLOWER (FUSE BOX RECEPTACLE BREAKER) VARIABLE ELECTRICAL RATING: SPEED CONNECTORS 120v, 60Hz, 0.9A CONTROL (NOT SUPPLIED) Note: If any of the original wire must be replaced, it must be replaced with type TEW minimum 16GA copper wire rated at 105°C Figure 17 - Optional Blower Wiring Diagram HEAT DEFLECTIVE HooD Front Hood...
  • Page 16: Operating Guidelines And Maintenance Instructions

    REPlaCEMENT PaRTs Note: Use only original replacement parts. When calling FMI PRODUCTS, LLC, have This will protect your warranty coverage for ready: parts replaced under warranty. • model and serial numbers of your heater •...
  • Page 17: Technical Service

    Purchase these accessories from your local dealer. If they can not supply these accessories call FMI PRODUCTS, LLC at 1-866-328-4537 for information. You can also write to the ad- dress listed on the back page of this manual. GA3750A An optional blower is available for use with the UVC-ST only firebox.
  • Page 18: Parts

    PaRTs MoDELS UVC-ST AND UV-ST 17** 10** 16** 16** 16** 11** 16** 16** 16** 16** 16** **These items are used on both sides of fireplace. www.fmiproducts.com 55473B...
  • Page 19 PaRTs MoDELS UVC-ST AND UV-ST This list contains replaceable parts used in your firebox. When ordering parts, follow the instructions listed under Replacement Parts on page 16 of this manual. NO. PART NO. DESCRIpTIoN QTY. Firebox Assembly • • Firebox Bottom •...
  • Page 20: Warranty

    This is FMI PRODUCTS, LLC’s exclusive warranty, and to the full extent allowed by law; this express warranty ex- cludes any and all other warranties, express or implied, written or verbal and limits the duration of any and all implied warranties, including warranties of merchantability and fitness for a particular purpose to one (1) year on new products and 30 days on factory reconditioned products from the date of first purchase.