Basic Remote Functions; Reset And Deletion; Long Term Event History - Directed Electronics Viper 5904 Installation Manual

Responder hd series security and remote start
Table of Contents

Advertisement

Basic Remote Functions

See Owner's guide for functionality details on both the HD and 1-way companion remote control.

Reset and Deletion

If a feature/virtual tach needs to be reset or the remote controls need to be deleted, use the following proce-
dure.
1. Open a door. (The green wire, H2/6, or the violet, H2/12 must be connected.)
2. Turn the ignition to the ON position (The heavy gauge pink wire must be connected).
3. Within 10 seconds, press and release the Control button: 2 times if you want to delete remotes, 3 times
to reset features or 4 times to reset virtual tach. These features are described next.
Delete remotes: This feature erases all remotes from the memory of the security system. This is useful
in cases when a customer's remote is lost or stolen.
Note: This does not reset the programmed features of the security system or reset the Virtual Tach
setting.
Reset Features: This resets features all of the security system to the factory default settings.
Note: This feature does not delete the remotes from the security system or reset the Virtual Tach set-
ting
Virtual Tach Reset: Deletes all previously learned values for Virtual Tach, and on the next remote start
sequence the unit begins virtual tach initialization.
Note: The "Zap" feature on the Bitwriter does not reset the Virtual tach setting.
4. Once you have selected the function step, press the Control button once more and hold it. The LED flashes
and the siren chirps to confirm the selected functional step. Do not release the Control button
5. While holding the control button, press the
the feature has been successfully reset.
Once the feature is reset, the Control button can be released.

Long Term Event History

The system stores the last two full triggers in memory. These are not erasable. Each time the unit sees a full trig-
ger, the older of the two triggers in memory is replaced by the new trigger. To access long term event history:
1. With the ignition Off, press and hold the Control button (on Control Center).
2. Turn the ignition On.
3. Release the Control button.
4. Within 5 seconds, press and release the Control button. The status LED flashes in groups indicating the last
two zones that triggered the unit for 1 minute or until the ignition is turned off. Refer to table of zones.
Note: The Warn Away triggers are not stored to memory and is not reported.
20
button on the remote control. The unit chirps to confirm that
AUX
© 2011 Directed Electronics. All rights reserved.