4. Siren Duration
1. 30sec: the siren output for full trigger activations and Panic mode is 30 seconds
2. 60sec: the siren output for full trigger activations and Panic mode is 60 seconds
5. Ign-controlled Locks
1. No Ign-locking: the door lock/unlock outputs will not activate when ignition is turned on/off
2. Lock & Unlock: the door lock & unlock output will activate when ignition is turned on & off
3. Lock Only: the door lock output will activate when ignition is turned on
4. Unlock Only: the door unlock output will activate when ignition is turned off
6. Door Lock Pulses
1. Single: the door lock & unlock outputs will pulse once
2. Double Unlock only: the unlock output only will pulse twice
3. Double Lock Only: the lock output only will pulse twice
4. Double Lock & Unlock: the lock & unlock outputs will pulse twice
7. Door Lock Output Duration
1. 0.8 sec.: the door lock output pulses will be 800 ms in duration
2. 3.5 sec.: the door lock pulses will be 3.5 seconds in duration
3. 0.4 sec.: the door lock pulses will be 400 ms in duration
8. Ignition Controlled 2nd Unlock
1. After first unlock: for Ign-controlled unlocking, the 2nd unlock will activate 800 ms after the first (driver
door) unlock
2. With first unlock: for Ign-controlled unlocking, the 2nd unlock will activate at the same time as the first
(driver door) unlock
9. Comfort Closure
1. No comfort Closure: Comfort Closure is defeated when arming
2. Comfort Closure 1: the door lock pulse (or 2nd pulse for double pulses) will remain on for 20 sec-
onds.
3. Comfort Closure 2: 800mS following the end of the door lock pulse (or 2nd pulse for double pulses);
the door lock output will turn on again for 20 seconds.
10. Horn Function
1. Full Alarm Only: the horn output will pulse only during full trigger events.
2. Siren Function 20/30/40/50ms: The horn output will emulate the siren output with selectable output
timing to compensate for OEM horn inefficiency.
11. Hood Switch Type
1. Normally Open: for vehicles with a hood switch that rests at ground when the hood is OPEN
2. Normally Closed: for vehicles with a hood switch that rests at ground when the hood is CLOSED
12. Sensor Full Trigger
1. Single: full trigger activation of only one sensor is required to fully trigger the alarm
2. Double: full trigger activation of two sensors within a ten second period is required to fully trigger
the alarm.
13. Door Switch Type
1. Normally Open: for vehicles with door switches that rest at ground when the door is OPEN
2. Normally Closed: for vehicles with door switches that rest at ground when the door is CLOSED
14. Trunk Switch Type
1. Normally Open: for vehicles with a trunk switch that rests at ground when the trunk is OPEN
2. Normally Closed: for vehicles with a trunk switch that rests at ground when the trunk is CLOSED
15. Remote Button Unlock (Ign off)
1. On: a message telling the 2-way remote control to unlock the keypad is sent each time the vehicle
ignition is turned off
2. Off: no message is sent
© 2011 Directed Electronics. All rights reserved.