Setting Individual Days (7 Day Commercial)
1. Press the
PROG
button. The display will switch to
programming mode. M (Monday) will appear and
the hour will flash.
2. Press
SYSTEM
to select HEAT or COOL.
3. Press
DAY/TIME
to select an individual day.
4. Press the SpeedBar
up or down to adjust the hour
®
for the OCCUPIED event. Press NEXT.
5. Press the SpeedBar up or down to adjust the
minute for the OCCUPIED event. Press NEXT.
6. Press the SpeedBar up or down to adjust the
temperature for the OCCUPIED event. Press NEXT.
7. Press the SpeedBar up or down to adjust the fan
setting for the OCCUPIED event. Press NEXT.
8. Repeat steps 4-7 for your UNOCCUPIED event.
9. If needed, repeat steps 3-7 to select other individual days.
10. If needed, repeat steps 2-9 to program the opposite mode (HEAT or COOL).
11. Press
RETURN
to exit.
User Manual
BACK
NEXT
BACK
and
NEXT
are
secondary functions of the
PROG
and
HOLD
buttons.
20

4 Operating Your Thermostat

Setting the SYSTEM Control Mode

The System Control has 5 modes of operation – AUTO, COOL, OFF, HEAT and EMER. The mode can be selected
by pressing the
SYSTEM
button to scroll through the different modes.
NOTE: Depending on how your thermostat was configured, some system modes may not be available.
AUTO
The system will cycle between heating and
cooling automatically based on your program
set points. AUTO will be displayed with
either HEAT or COOL.
COOL
Only your cooling system will operate.
OFF
Heating and cooling systems are off.
HEAT
Only your heating system will operate
EMER
Operates a backup heat source
(Emergency Heat) for heat pump systems
only (Model 5220 only).