Samsung SIA-0100Q User Manual page 10

Long-range ir sensor
Hide thumbs Also See for SIA-0100Q:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Wiring
1)
Normal
3)
If using both Alarm Out and Environment Out
4)
If using the Re-transmitting function
5)
Available range according to the wiring
Wire Gauge
AWG 22
AWG 20
AWG 18
AWG 14
Z6806119901A-SIA-0100Q,0200Q.ind10 10
Z6806119901A-SIA-0100Q,0200Q.ind10 10
2) If two pairs are connected directly
Max Distance (meter)
SIA-0100Q
12V DC
24V DC
100
900
190
1,700
280
2,600
600
5,370
English _10
SIA-0200Q
12V DC
24V DC
90
800
160
1,500
250
2,200
500
4,570