INSTALLATION CHECKLIST

Water Heater Location
Centrally located with the water piping system.
The fl ooring beneath the water heater must be able to
support the weight of the water heater when fi lled with
water (Table 1).
Located indoors (such as a basement or garage)
and in a vertical position. Sheltered from freezing
temperatures.
Provisions made to shelter the area from water
damage. Metal drain pan installed and piped to an
adequate drain.
Sufficient room to service the water heater.
The water heater must have unrestricted airflow and
requires a minimum installation space of 700 cubic feet.
As an example, a room that has an eight foot tall ceiling
and is 10 feet long by 8-3/4 feet wide would contain
700 cubic feet.
NOTE: This Heat Pump Water Heater may be located
within a required minimum
wall on the outlet side, however for future service
considerations a minimum clearance of 3 feet from
any obstruction on the back, left and right side is
recommended.
The unit cannot be placed into any type of closet or
small enclosure, unless adequate provision is made for
air exchange (vented or louvered doors, etc.).
The site location must be free from any corrosive
elements in the atmosphere such as sodium, sulfur,
fl uorine, and chlorine. These elements are found
in aerosol sprays, detergents, bleaches, cleaning
solvents, air fresheners, paint, and varnish removers,
refrigerants, and many other commercial and
household products. In addition excessive dust and
lint may affect the operation of the unit and require
more frequent cleaning (See "Preventive Maintenance"
section).
Ambient air temperature should be above 45°F /
7.2°C and below 120°F / 48.8°C. If the ambient air
temperature falls outside these upper and lower limits
the electrical elements will activate to meet the hot
water demand.
Water System Piping
Temperature and pressure relief valve properly
installed with a discharge pipe run to an adequate drain
and sheltered from freezing (Figure 8).
All piping properly installed and free of leaks.
Heater completely filled with water (See "Water Piping
System" section).
Closed system pressure buildup precautions installed
(See "Closed System/Thermal Expansion" section).
Mixing valve (when applicable) installed per
manufacturer's instructions (See "Water Temperature
Regulation" section).
Condensate Drain Line Installation
10
of 6" clearance from a
Must be located with access to an adequate drain or
condensate pump.
Condensate drain lines installed and piped to an
adequate drain or condensate pump (Figure 4).
Electrical Connections
This water heater requires a 240 VAC single phase 30
amp power supply. DO NOT use a 208 VAC service.
Wiring size and connections comply with all applicable
codes or in the absence of local or state codes follow
NFPA-70, the National Electrical Code-current edition.
Water heater and electrical supply are properly
grounded.
Wiring enclosed in approved conduit (if required by
local codes).
Proper overload fuse or circuit breaker protection
installed.
Post Installation Review
Understand how to use the User Interface Module to
set the various modes and functions (See "Adjusting
the User Interface Module/Operating Modes" section).
Hybrid Mode is the recommended Operating Mode.
Understand the various Operating Modes and which
mode may be best based on season, ambient
temperature, and usage (See "Operating Mode
Description" section).
Understand the importance of routine inspection/
maintenance of the condensate drain pan and lines
(See
"Inspection/Cleaning of the Condensate Drain
Pan & Condensate Drain Lines"
help prevent any possible drain line blockage resulting
in the condensate drain pan overflowing.
IMPORTANT: If water is coming from the overflow-
slot of the condensate drain pan cover (Figure 11) this
indicates that both condensation drain lines may be
blocked. Immediate action is required.
Figure 11
Drain Pan Cover
Secondary Drain
Primary Drain
Overflow-Slot
To maintain optimal operation, check, remove and
clean the air filter as needed(See "Air Filter Cleaning/
Replacement" section).
The Installation Instructions and Use & Care Guide
should be kept with the water heater for reference.