Water Temperature Control - LG WM0742H Series Training Manual

Steam washer
Hide thumbs Also See for WM0742H Series:
Table of Contents

Advertisement

TRAINING MANUAL
PREWASH CYCLE
Cold water is supplied via the dispenser when the prewash valve opens. If COLD WASH /
COLD RINSE is selected, the heater is not activated. If another WASH / RINSE temper-
ature is selected, the heater still is not activated during the PREWASH unless the water
temperature is lower than 85° F (29° C).
MAIN WASH and RINSE CYCLE
At the beginning of the prewash cycle, COLD water is supplied via the dispenser when
the prewash valve opens. Then HOT or COLD water is applied as required to create a
wash of the programmed temperature, as shown in the table below.
Set Point
Range (Wash)
Range (Rinse)
As used in the chart, the set point is the specified temperature setting (hot, warm, cold,
et al) as recommend by the clothing manufacturers. In times past, HOT was whatever
came out of the hot water faucet, COLD was whatever came out of the cold water faucet,
and WARM was what happened with both valves opened. The washing machine uses a
thermistor and computer to regulate the water input, adding hot or cold water as needed
to adjust the temperature. If the washer cannot achieve the desired temperature with
the addition of hot water to the tub, the heater will be activated and continue to operate
until the desired temperature is achieved. When the desired setting is reached, the
heater is turned off, and it will not come on again unless the temperature of the water in
the tub decreases by 36°F (20° C.) For example, in the case of a HOT wash, when the
water is heated to 122°F (50° C.)
In example 1, HOT / COLD temperatures are chosen for a NORMAL cycle. The prewash
valve is opened and cold water is supplied briefly, then the hot valve is opened and water
fills the tub until it reaches 131° F. As 131°F is hotter than the set point for HOT
washing (122°F), the cold valve is opened to regulate the temperature to 122°F and the
heater is never energized because the water temperature meets the target.
WM0742HGA

WATER TEMPERATURE CONTROL

EXTRA
HOT
HOT
158°F
122°F
158~167
122~131 104~113
Page 25
WARM
COLD
104°F
86°F
50~86
Tap
68~77
continued on next page