Green Tube Connection

Step 19
Connect the green tube from the RO module to the adapta valve that is connected to the
Angle Stop Valve. Leave enough tube so it is not kinked and cut the tube to desired length.
Step 20
Remove a brass nut, plastic sleeve and brass insert from the
parts bag. Place nut on the tube first, then the plastic sleeve
(small taper end of plastic sleeve must point to the end of tube)
and then insert the brass Insert into the end of the tube.
Step 21
Insert the green tube into the ¼" opening on the adapta valve
until it stops. Slide nut and sleeve down and thread onto the
male pipe threads. Use a ½" wrench to securely tighten.

Blue Tube Connection

Step 22
Position tank in desired location. Stand it upright or lay it on its
side (using the black plastic stand). Measure the blue tube from
the RO module over to the tank and cut it to length.
Step 23
Assemble brass nut plastic sleeve and brass insert on to blue
tube. Push blue tube into the brass tee until it stops. Slide brass
nut and plastic sleeve down until you can thread nut onto the
tee. Use wrench to securely tighten the nut, while pushing tube
into the tee.