INSTRUMENT PANEL AND GAUGES
8E - 1
INSTRUMENT PANEL AND GAUGES
OWERDRIWE LOCKOUT SWITCH
REMOVAL
(1) Locate bracket holding chime module and inter-
mittent wipe module (Fig. 2).
(2) Remove 2 nuts holding bracket to instrument
panel support.
(3) Remove ground straps and bracket.
(4) Depress lock tabs on switch and push i t out of
the instrument panel.
INSTALLATION
(1) Hold wiring connector in switch opening.
(2) Push switch on to wiring connector.
(3) Continue to push until switch snaps into place.
(4) Install bracket with modules. Be sure ground
straps are installed.
GROUND
COMBINATION
BUZZER
J918E-37
Fig. 1 Overdrive
Lockout
Switch
Location
INTERMITTENT
WIPER MODULE
BRACKET
INTERMITTENT WIPER
CONTROL MODULE
J918E-36
Fig. 2 Intermittent
Wiper
Module
Bracket