AIR DEFLECTORS
VERTICAL DEFLECTORS
HORIZONTAL DEFLECTORS
Vertical deÁ ectors at both sides of outlets can be set to
Horizontal deÁ ectors at both sides of the outlets can
either auto-swing or static position to direct discharge air
be set to direct discharge air upward, downward or
rightward, leftward or forward direction.
forward direction.
CAUTIONS
To avoid dew forming on the deÁ ectors which eventually may drip to the Á oor, please do not adjust horizontal deÁ ectors
extremely downward position or vertical deÁ ectors extremely leftward or rightward position during cool operation for a long
time.
Also, do not adjust the vertical deÁ ectors position by hand or any other object.
AIR EXHAUST LEVER
Set the air exhaust lever to the down ( OPEN) position for air ventilation in
the room. The air exhaust lever should normally be kept in up ( CLOSE)
position during cooling operation and in the case of typhoon.
AIR PURIFYING FILTER
Always stop the operation before installing the air purifying À lter.
1. Pull and remove the suction grille
2. Remove the pre-À lter
3. Install the air purifying À lter in
the frame
4. Install back the pre-À lter and
close the suction grille
Air purifying À lter is washable and can be use for 1 year time. Type number for this air purifying À lter is <SPX-CFH8W>.
Please use this number for ordering when you want to renew it.
NOTES ON OPERATION
TEMPERATURE AND HUMIDITY
Avoid to use the room air conditioner for cooling operation when the outside temperature is below 21°C (70°F). Recommended
operation humidity should be below 80%. Continuous operation at over 80% humidity (indoor) will cause some dews form
on the outlet grille and deÁ ectors of the unit.
NOISE
In a quiet environment during the starting or stopping the operation, phenomena like Á owing sound of refrigerant in the
refrigerating cycle and rubbing noise from the fan casing may occasionally occur, but this is normal for the operation.
Water will be condensed on the evaporator coil and collected in the bottom tray, it is picked up by the condenser fan and
blown onto the condenser coil, this creates a “splashing” sound which is normal.
ODOR
The odor will possibly be emitted from the room air conditioner especially at the starting of operation and in a high
humidity condition. This is not abnormal phenomena because of the various kind of odors emitted by smoke, food stuffs,
cosmetics and others which may stick to the room air conditioner. So, the pre-À lter and the evaporator regularly must be
cleaned to reduce the odor.
THE IDEAL WAYS OF OPERATION
Ventilation
Install curtain or blinds
Suitable Ro
Temperature
Caution
Warning
It is possible
Do not close the room for a long period of
to reduce heat
Freezing temperature
time. Occasionally
entering the room
is bad for health and a
open the door and
through windows.
waste of electric power.
windows to allow the
entrance of fresh air.
Please Adjust Suitable Temperature
Do Not Forget To Clean The Pre-Filter
For Baby And Children
Dusty pre-À lter will reduce the air
Please pay attention to the
volume and the cooling efÀ ciency.
room temperature and air Á ow
To prevent from wasting electric
direction when operating the
energy, please clean the pre-À lter
unit for baby, children and old
every 20 days.
people who have difÀ culty in
movement.
FOR USER’S INFORMATION
The Air Conditioner And The Heat Source In The Room
Caution
If the amount of heat in the room is above the cooling capability of the air conditioner (for
example: more people entering the room, using heating equipments and etc.), the preset
room temperature cannot be achieved.
When Lightning Occurs
Warning
To protect the unit during lightning, please stop operating the unit and remove the plug
from the socket.