Kenmore 153.336930 Use & Care Manual page 37

30/40 gallon tall
Hide thumbs Also See for 153.336930:
Table of Contents

Advertisement

status light will flash a code (4 flashes), indicating an over-
temperature condition and the main burner will be shut off.
If a high temperature condition occurs, turn the main gas
supply OFF and have the water heater repaired by a qualified
service technician.
Contact Sears at 1-800-4-MY-HOME
(1-800-469-4663) to request service.
Leakage Checkpoints
A
C
E
D
B
H
G
I
F
FIGURE 38.
Read this manual first. Then, before checking the water heater,
make sure the gas supply has been turned “OFF”, and never
turn the gas “ON” before the tank is completely full of water.
Never use this water heater unless it is completely filled with
water. To prevent damage to the tank, the tank must be filled
with water. Water must flow from the hot water faucet before
turning “ON” gas to the water heater.
A. Water at the draft hood is water vapor which has condensed
out of the combustion products.
This is caused by a
problem in the vent. Contact a qualified technician.
B. *Condensation may be seen on pipes in humid weather or
pipe connections may be leaking.
C. *The anode rod fitting may be leaking.
D. Small amounts of water from temperature-pressure relief
valve may be due to thermal expansion or high water
pressure in your area.
E. *The temperature-pressure relief valve may be leaking at
the tank fitting.
F.
Water from a drain valve may be due to the valve being
slightly opened.
G. *The drain valve may be leaking at the tank fitting.
H. Combustion products contain water vapor which can
condense on the cooler surfaces of the tank. Droplets form
and drip onto the burner or run on the floor. This is common
at the time of start-up after installation and when incoming
water is cold.
I.
Water in the water heater bottom or on the floor may be
from condensation, loose connections, or the relief valve.
DO NOT replace the water heater until a full inspection
of all possible water sources is made and necessary
corrective steps taken.
Leakage from other appliances, water lines, or ground seepage
should also be checked.
*
To check where threaded portion enters tank, insert cotton
swab between jacket opening and fitting. If cotton is wet, follow
draining instructions in the “Draining and Flushing” section and
then remove fitting. Put pipe dope or teflon tape on the threads
and replace. When you are finished, follow the steps in “Filling
the Water Heater” in the Installation Instructions earlier in this
manual.