22 | Vertical configurability
4. Remove and retain Electric Heat
Element(s).(Figure#74)
Figure # 74
5. Disconnect main Electric Heat E-box
plug.(FIgure#75)
Figure # 75
6. Remove and retain Electric Heat E-box by
removing (2) screws.(Figure#76)
Figure # 76
6 720 220 406 (2013/1)
7. Re-install Electric Heat E-box in the new
location. (Figure#77)
8. Remove and retain Blower collar cover(s).
(FIgure#78)
9. Re-install Electric Heat Elements in the new
location. Ensure High Temperature Cutouts are
located on the left side. (Figure#79)
Subject to change without prior notice