Needle Bearing Lubrication; Adjustment Of The Oil Pump; Cooling System; Air Injection" Centrifugal Cleaning - Husqvarna 1151436-95 Operator's Manual

Epa i epa iii
Table of Contents

Advertisement

Needle bearing lubrication

The clutch drum has a needle bearing on the output shaft.
This needle bearing must be lubricated regularly (once a
week).
When lubricating, remove the clutch cover by loosening
the two bar nuts. Lay the saw on its side with the clutch
drum upwards.
Lubrication involves grease being squirted into the centre
of the crankshaft using a grease gun.

Adjustment of the oil pump

The oil pump is adjustable. Adjustments are made by
turning the screw using a screwdriver or combination
spanner. The machine is supplied from the factory with
the screw set to position 2. Turning the screw clockwise
will reduce the oil flow and turning the screw anti-
clockwise will increase the oil flow.
1
2
3
Recommended settings:
Bar 13"-15": Position 1
Bar 15"-18": Position 2
Bar 18"-20": Position 3
WARNING! The engine must be stopped
!
when making adjustments.
36 – English
MAINTENANCE
+

Cooling system

To keep the working temperature as low as possible the
machine is equipped with a cooling system.
The cooling system consists of:
1
Air intake on the starter.
2
Air guide plate.
3
Fins on the flywheel.
4
Cooling fins on the cylinder.
5
Cylinder cover (directs cold air over the cylinder).
5
4
3
2
1
Clean the cooling system with a brush once a week, more
often in demanding conditions. A dirty or blocked cooling
system results in the machine overheating which causes
damage to the piston and cylinder.
Note! The cooling system on a chain saw with catalytic
converter must be cleaned daily. This is particularly
important on chain saws with catalytic converters,
because the higher exhaust temperature requires
efficient cooling of the engine and the catalytic converter
unit.
"Air Injection" centrifugal
cleaning
Centrifugal cleaning means the following: All air to the
carburetor passes through the starter. Dirt and dust is
pushed out by the cooling fan.
IMPORTANT! In order to maintain operation of the
centrifugal cleaning system it must be regularly
maintained. Clean the air intake to the starter, the fins on
the flywheel, the space around the flywheel, inlet pipe and
carburetor compartment.

Advertisement

Table of Contents
loading

This manual is also suitable for:

359 epa iii357xp359