Electrical - STA-RITE SilentFlo SF550100 Owner's Manual

Installation, operation and service
Table of Contents

Advertisement

Certified Anti-entrapment
Cover or Suction Fitting,
screw fastened to Main
Suction Outlet
(Main Drain)

Electrical

Electrical installation shall be in accordance with the national wiring rules (AS/NZS
3000) taking into account its ratings (Class I, IPX5). The pump is supplied with a
standard Australian 10 amp plug and 2 metres of cord. Select the correct Pool Zone
for installation.
Using the tapped hole terminal and tin plated copper lug connect the equipotential
bonding conductor to the pump if required. The terminal is on the motor side of the
fl ange. Remove paint from the terminal surface and use M5x12 zinc plated screw with
lock washer or similar to secure the termination.
An RCD with maximum rated residual current of 30mA is required for the power supply
to the pump. Additionally, if a suitable socket outlet is not available a weatherproof
socket must be installed by an electrician in a suitable location. RCD tripping indicates
an electrical problem. If RCD trips and will not reset have a qualifi ed electrician inspect
and repair electrical system.
Do not use extension leads as they are unsafe in and around the Pool Zone.
Incorrect voltage can cause fi re or seriously damage pump and voids warranty.
WARNING
Hazardous voltage.
Can shock, burn or
cause death.
No valves between Tee
Drain Sump
Valves OK between
pump and Tee
Voltage at pump must not be more than 6% above or
10% below motor nameplate rated voltage or pump
may overheat, causing overload tripping and reduced
component life. If voltage is less than 90% or more than
106% of rated voltage when pump is running at full load,
consult the power company.
To avoid dangerous or fatal electrical shock, turn OFF
power to pump and remove plug from outlet before
working on electrical connections.
The power supply cord has a type 'Y' attachment and if
service is required to the power cord, it must be replaced
with the specialised power cord assembly by Pentair
Water service agent or similarly qualifi ed personnel in
order to avoid a hazard. Warranty is void if unauthorised
modifi cations are made to any component.
800mm
Certified Anti-entrapment
and Main Drains
8
Cover or Suction Fitting,
screw fastened to Main
Drain Sump
Suction Outlet
(Main Drain)
Pump