Sony PDW-1500 Operation Manual page 103

Professional disc recorder
Hide thumbs Also See for PDW-1500:
Table of Contents

Advertisement

Menu items in the 600s, relating to the time code, metadata, and UMID
Item number Item name
607
U-BIT BINARY GROUP FLAG
611
TC OUTPUT PHASE IN EE MODE
612
TC OUTPUT MUTING IN SEARCH
MODE
619
VITC
626
TC MODE
627
RUN MODE
628
DF MODE
Settings
Select the user bits to be used in the time code generated by the time
code generator.
000 (000:not specified): Character set not specified.
001 (001:iso character): 8-bit characters compliant with ISO 646 and
ISO 2022.
010 (010:unassigned-1): Undefined.
011 (011:unassigned-2): Undefined.
100 (100:unassigned-3): Undefined.
101 (101:page / line): SMPTE 262M page/line multiplex system.
110 (110:unassigned-4): Undefined.
111 (111:unassigned-5): Undefined.
Select the time code output mode for output from the TIME CODE OUT
connector in E-E mode.
mutng (muting): Suppress the output.
thru (through): Output the time code input to the TIME CODE IN
connector as it is.
v-in (video input phase): Output the time code with the same phase as
the input video signal phase.
v-out (video output phase): Output the time code with the same phase
as the output video signal phase.
Select whether to suppress the output from the TIME CODE OUT
connector in jog/shuttle mode.
on: Suppress.
off: Do not suppress.
Specify whether or not to record the VITC generated by the internal time
code generator.
off: Do not record internally generated VITC.
on: Record internally generated VITC.
Note
Even if this item is set to "off," VITC is recorded if the input video signal
contains VITC and the VITC line is set to "thru" with item 723.
Select the time code recording mode.
i-prs (int preset): Set an initial value, then record the output of the
internal time code generator.
i-reg (int regen): Record the output of the internal time code generator,
initialized to time code following continuously upon the time code of
the last frame of the last clip on the disc. When clips files are written
or transferred via a FAM or FTP connection, the time code of the clip
is recorded so that it is continuous with the time code of the last
frame of the last clip on the disc.
e-reg (ext regen): Record the output of the internal time code generator,
synchronized to an external time code generator.
r-reg (rp188 regen): Record the output of the internal time code
generator, synchronized to SMPTE RP188 LTC in an SDI signal.
e-prs (ext preset): Directly record the input of an external time code
generator.
See 4-1-2 "Recording Time Code and User Bit Values" (page 43) for
more information about time code recording modes.
When item 626 is set to "int preset," select the run mode of the internal
time code generator.
free (free run): Time code advances continually.
rec (rec run): Time code advances only during recording.
In 525(U)/525(J) line modes, when item 626 is set to "int preset," select
the frame mode of the internal time code generator and counter.
df (on (df)): Drop-frame mode
ndf (off (ndf)): Non-drop frame mode
103
8-3 Extended Menu

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents