5
DATA
5-1. REFILLING REFRIGERANT CHARGE (R410A : kg)
Service Ref.
PUHZ-SW40VHA
PUHZ-SW40VHA-BS
PUHZ-SW50VHA
PUHZ-SW50VHA-BS
5-2. COMPRESSOR TECHNICAL DATA
Service Ref.
Compressor model
U-V
Winding
U-W
Resistance
(
)
W-V
5-3. NOISE CRITERION CURVES
PUHZ-SW40VHA(-BS)
90
80
70
60
50
40
30
20
APPROXIMATE
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
10
63
125
250
BAND CENTER FREQUENCIES, Hz
OCH525
10m
20m
2.1
2.3
2.1
2.3
Additional charge is required for pipes
longer than 10 m.
(at 20°C)
PUHZ-SW40VHA(-BS)
PUHZ-SW50VHA(-BS)
SNB130FGCM2
0.64
0.64
0.64
MODE
SPL(dB)
LINE
COOLING
45
HEATING
45
500
1000
2000
4000
8000
MICROPHONE
1.5m
Piping length (one way)
30m
40m
2.5
2.7
2.5
2.7
PUHZ-SW50VHA(-BS)
90
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
APPROXIMATE
THRESHOLD OF
HEARING FOR
NC-20
CONTINUOUS
NOISE
10
63
1m
8
50m
60m
75m
2.9
—
—
2.9
—
—
MODE
COOLING
HEATING
125
250
500
1000
BAND CENTER FREQUENCIES, Hz
UNIT
GROUND
Initial
charged
2.5
2.5
SPL(dB)
LINE
46
46
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
2000
4000
8000